Display for magnetic band

F18-K

Date: 13/01/16

File: F18_K ing.doc

5/8

%.+

%.+

%.+

%.+

Count direction

Set out the count direction of the display, range allowed 0 or 1.
Setting 0, the value on the display increases moving the sensor to the right (sensor as per draw on page 1).
Setting 1, the value on the display increases moving the sensor to the left.

//

//

//

//

Keys opening mode

This parameter programs the functions linked to the keys.
The value to set is a number of three digits so each key corresponds to a digit; the digit on the right stands for
setting of key 

RESET

, the digit in the middle stands for key   while the last digit on the left stand for key 

 .

The values allowed are the following:

VALUE

KEY   

KEY   

KEY  

RESET

0

Not open

Not open

Not open

1

Function

 ABS

/

REL

Conversion mm/inch

Reset

2

Not open

Display  in degrees

Preset

3

Not open

Not open

Fast Preset

4

Not open

Not open

Change of origin 0,1,2

Reset: 

function

 

of reset of quota, pressing on key 

RESET

 the quota is zero-set .

Preset:

 function of preset of quota, pressing on key 

RESET

 the quota on the display became the same of the

one set in parameter Preset. The setting of Preset value appears immediately after parameter 

//

//

//

//

 (if

chose value 2).

Fast

 

Preset: 

the fast setting of the quota on the display, pressing on key 

RESET

 appears Preset and pressing

still 2 times 

RESET

 is possible to set the value directly (use keys        

  and confirm with 

RESET

). This

function  is useful when the quote on the display has often be corrected.

Origin change 

(quota correction for tool change): with this function 3 different origins (0,1,2) are

programmable  and passes from an origin to the other wit key 

RESET

. Activating the function of origin change

on the display appear two small arrows  and the indication of the selected origin  happens with the switching
on of the origin indicators (see paragraph meaning of symbols ). After setting 4 in the first digit on the right of

//

//

//

//

, will appear PrS0 and pressing 2 times 

RESET

 has to be set the value to be read in this position of

sensor for origin 0, confirm with 

RESET

. It will appear PrS1 which is the value to be read for origin 1 in the

present position of sensor: set the correct value and confirm with 

RESET

. It will appears PrS2  which is the

value to be read for origin 2 in the present position of sensor: set the correct value and confirm with 

RESET

. It

means PrS0, PrS1, PrS2 are references for the calibration, in a certain position of the sensor, in three
different origins.

Function 

ABS

/

REL

:

 

Enables the pass from absolute to relative value, pressing key 

  zero-set temporary the

value to allow a relative shifting. On the display switches on indicator REL to indicate that the  current quote is
relative to the zero-point just created. Pressing still key 

 reappears the absolute value and on the display

switches on the indicator ABS.

Conversion mm/inch:

 Pressing key  converts the measure from millimeter to inches and back with

indication of inch/mm on the display and a decimal number more then for millimeters.  By choosing 5
decimals for millimeters the conversion in inches is not allowed.

Visualization in degrees: 

Pressing on key    on the display appears Deg to indicate the visualization of

measure in degrees.

,/

,/

,/

,/

Origin displacement

This parameter is added or subtracted from the current quota to correct the value showed on the display, for
example following wear or changing of tool. Setting a positive value on display appears the current quota added
to this value.
Set zero to exclude the offset function (manufacturer’s value).
The offset is not available if the function of tool-change is selected.

Содержание F18-K

Страница 1: ...Display for magnetic band F18 K Date 13 01 16 File F18_K ing doc 1 8 USER AND MAINTENANCE MANUAL F18 K DISPLAY FOR MAGNETIC BAND WITH INTERNAL BATTERY POWER SUPPLY ...

Страница 2: ...d to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The instrument does not needs a particular maintenance except cleaning to do only with a soft clo...

Страница 3: ...nt tools and the offset function for balancing of tool wear On the display all activated functions are showed by a symbol The keys enabling to recall the preset dimension and the absolute relative dimension switches may be inhibited in a very simply way On the display all activated functions are showed by a symbol The power supply is internal with 2 batteries type AA of 1 5V one year life The run ...

Страница 4: ...arameter press two times RESET one time displays only the value and with keys and set the wanted value to be confirmed with RESET To go out of the programming press 0 0 0 0 Value to be displayed for 100 mm of sensor displacement This parameter together with the following allows the programming of the value on the display for a certain displacement of the sensor It means that is necessary to set th...

Страница 5: ...ar two small arrows and the indication of the selected origin happens with the switching on of the origin indicators see paragraph meaning of symbols After setting 4 in the first digit on the right of will appear PrS0 and pressing 2 times RESET has to be set the value to be read in this position of sensor for origin 0 confirm with RESET It will appear PrS1 which is the value to be read for origin ...

Страница 6: ...ollows placed on a side of the instrument Take off the cover and take out the battery holder and change the batteries paying attention to the polarity indicated Without batteries the instrument switches off in this phase do not rotate the hollow shaft to avoid loosing of correct quota As soon as the batteries are fitted inside the instrument switches on with the same value on the display as at the...

Страница 7: ... 01 16 File F18_K ing doc 7 8 Dimensions Connection scheme for versions with connector View of the male connector on the back of the instrument Note the connection of the shield is always necessary 1 2 3 1 BROWN 2 WITHE 3 YELLOW GREEN SHIELD ...

Страница 8: ...display IP67 sensor Sensor cable Length 0 5 1 3 5 meters Material PUR Ø5 5mm suitable for movable wiring cable Sensor house aluminum black Dimensions 48x72 depth 60mm Gap sensor magnetic strip 1mm max Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via ...

Отзывы: