Manual purpose

This manual has been designed by the Manufacturer to provide the necessary information regarding the
instrument F18_ to those who are authorized to carry out safely its installation, maintenance, dismantling and
disposal. All the necessary information for the buyers and planners can be found in the Sales catalogue.
Other than adopting good technical construction methods, the information should be read carefully and
strictly applied. Inobservance of this information could cause risks for the health and safety of people and
economical damage. This information, provided by the Manufacturer in the original language(Italian) is also
available in other languages to satisfy legislative and/or commercial needs. This manual must be kept in good
conditions by a responsible person in an ideal place so that it is always available for consultation. In case this
manual is lost or deteriorates, a replacement should be requested directly from the manufacturer quoting the
manual’s code. This manual reflects the state of skill of the instrument at the time of input on the market:
however the manufacturer reserves the right to make changes, add or improve the manual without giving any
reason to hold the present manual inadequate.

Identification of the equipment

The identification plate represented is applied on the instrument.
To find out the identification code of the instrument, consult the sales catalogue.

Environmental conditions

Temperature setting: min. 0°C, max. + 50°C.
It is forbidden to use the instrument other than its specific use and in potentially explosive conditions or where
anti- explosive elements are used.

Storage

Here below are some references to be followed for the storage of the instrument.
Avoid environments with excessive humidity and those exposed to bad weather (avoid open areas). Avoid
putting the instrument directly on the ground. Store the instrument in its original packing.

Conformity declaration and EC marking

The instrument answers to the following Communitarian Directives:
2014/30/EU Electromagnetic compatibility, 2011/65/EU RoHS.

Maintenance

The instrument does not needs a particular maintenance except cleaning to do only with a soft cloth dampen
with ethylic alcohol or water. Do not use hydrocarbon solvents (petrol, diluents, etc.): the using of these
products could affect the proper functioning of the instrument.
Reparations should be done only and exclusively at the FIAMA technical assistance center.

Calibrations and tests

It is advisable to calibrate the instrument periodically, once every working year.
To do the calibration, follow the calibration procedure indicated in the present manual.

Assistance request procedure

For any kind of technical assistance request, contact the sales department of the Manufacturer directly
indicating the information given on the identification plate, the number of hours used and the type of defect.

Manufacturer’s responsibility

The manufacturer declines any responsibility in case of :
• Using the instrument contrary to the national safety and accident-prevention laws.
• Wrong installation, inobservance or wrong procedures of the instructions provided in the present manual.
• Defective electrical power supply.
• Modifications or tampering.
• Operations carried out by untrained or unqualified staff.
The safety of the instrument also depends on the strict observance of the procedures indicated in the
manual: always operate the instrument in its functioning capacity and carry out a careful routine maintenance.
• All phases of inspection and maintenance should be done by qualified staff.
• The configurations provided in the manual are the only ones permitted.
• Do not try to use it anyway contrary to the indications provided.
• The instructions in this manual do not substitute but accomplish the obligations of the current legislation
regarding the safety laws.

Содержание F18-K

Страница 1: ...Display for magnetic band F18 K Date 13 01 16 File F18_K ing doc 1 8 USER AND MAINTENANCE MANUAL F18 K DISPLAY FOR MAGNETIC BAND WITH INTERNAL BATTERY POWER SUPPLY ...

Страница 2: ...d to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The instrument does not needs a particular maintenance except cleaning to do only with a soft clo...

Страница 3: ...nt tools and the offset function for balancing of tool wear On the display all activated functions are showed by a symbol The keys enabling to recall the preset dimension and the absolute relative dimension switches may be inhibited in a very simply way On the display all activated functions are showed by a symbol The power supply is internal with 2 batteries type AA of 1 5V one year life The run ...

Страница 4: ...arameter press two times RESET one time displays only the value and with keys and set the wanted value to be confirmed with RESET To go out of the programming press 0 0 0 0 Value to be displayed for 100 mm of sensor displacement This parameter together with the following allows the programming of the value on the display for a certain displacement of the sensor It means that is necessary to set th...

Страница 5: ...ar two small arrows and the indication of the selected origin happens with the switching on of the origin indicators see paragraph meaning of symbols After setting 4 in the first digit on the right of will appear PrS0 and pressing 2 times RESET has to be set the value to be read in this position of sensor for origin 0 confirm with RESET It will appear PrS1 which is the value to be read for origin ...

Страница 6: ...ollows placed on a side of the instrument Take off the cover and take out the battery holder and change the batteries paying attention to the polarity indicated Without batteries the instrument switches off in this phase do not rotate the hollow shaft to avoid loosing of correct quota As soon as the batteries are fitted inside the instrument switches on with the same value on the display as at the...

Страница 7: ... 01 16 File F18_K ing doc 7 8 Dimensions Connection scheme for versions with connector View of the male connector on the back of the instrument Note the connection of the shield is always necessary 1 2 3 1 BROWN 2 WITHE 3 YELLOW GREEN SHIELD ...

Страница 8: ...display IP67 sensor Sensor cable Length 0 5 1 3 5 meters Material PUR Ø5 5mm suitable for movable wiring cable Sensor house aluminum black Dimensions 48x72 depth 60mm Gap sensor magnetic strip 1mm max Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via ...

Отзывы: