FIAMA EP9L Скачать руководство пользователя страница 4

Hollow shaft display

EP9L

Data: 06/11/18

EP9L_ing.doc

pag 4/7

blink the decimal pinpoint and with key   it can be moved to the wanted position. Confirm with

RESET

.

The range allowed is from 0,0001 to 99999 with setting of decimal point position that is, after
programming of the last digit on the left, pressing key 

  will blink the decimal pinpoint and with

key   it can be moved to the wanted position.  Confirm with 

RESET

.

+%

+%

+%

+%

Number of decimal digits

It is the number of decimal digits to visualize on the display, range allowed from 0 to 4.
Example: for each turn of the hollow shaft it is necessary to display 12.345 with only two decimal
places, set   

0

0

0

0

=12.345 and 

+%

+%

+%

+%

=2

//

//

//

//

Keys opening mode

This parameter programmes the functions linked to the keys.
The value to set is a number of three digits so each key corresponds to a digit; the digit on the
right stands for  setting of key 

RESET

, the digit in the middle stands for key   while the last digit on

the left stand for key 

 .

The values allowed are the following:

VALUE

ENTER

/

RESET

0

Not active

Not active

Not active

1

mm/inch conversion

abs/rel

measurement

Reset

2

Not active

Not active

Preset

3

Not active

Not active

Fast Preset

4

Not active

Not active

Change of origin

0,1,2

5

Not active

Not active

Offset

6

Not active

Not active

Fast Offset

7

Not active

Not active

Delayed reset *

(after 3s)

8

Not active

Not active

Delayed preset *

(after 3s)

* Delayed means that to activate the function (reset or preset), it is necessary to keep

ENTER

/

RESET

 pressed for approximately 3 s.

Reset:

 reset function

 

of the displayed value; after pressing 

ENTER

/

RESET

,

 the displayed value is

set to zero.

Preset:

 preset function of the displayed value; after pressing 

ENTER

/

RESET

,

 the displayed value

becomes equal to the value in the 

3U6W

3U6W

3U6W

3U6W

parameter, which can be set immediately after 

W$6W,

W$6W,

W$6W,

W$6W,

(when the digit on the right is set to 2).

Fast

 

Preset: 

the fast setting of the displayed value on the display; after pressing 

ENTER

/

RESET

3U6W

3U6W

3U6W

3U6W

 appears and pressing 2 times 

ENTER

/

RESET

 it is possible to set the value directly (use   and

 and then confirm with 

ENTER

/

RESET

). This function is useful when the displayed value must be

corrected often.

Origin change 

(correction of the displayed value for tool changes): with this function 3 different

origins (0,1,2) can be set and with 

ENTER

/

RESET 

it is possible to switch from one origin to another.

After setting 4 in the first digit on the right of the 

W$6W,

W$6W,

W$6W,

W$6W,

parameter, 

3U6

3U6

3U6

3U6

 will appear and after

pressing 2 times 

ENTER

/

RESET

 it is possible to set the nominal value for tool 0 (for example the

radius of cutter 0), which is then confirmed by pressing 

ENTER

/

RESET

.

Now 

3U6

3U6

3U6

3U6

 will appear which is the nominal value for tool 1 (for example the radius of cutter 1): set

the correct value and confirm with 

ENTER

/

RESET

.

Содержание EP9L

Страница 1: ...Hollow shaft display EP9L Data 06 11 18 EP9L_ing doc pag 1 7 USER S MANUAL AND MAINTENANCE ELECTRONIC HOLLOW SHAFT DISPLAY BATTERY SUPPLIED TYPE EP9L ...

Страница 2: ...ow are some references to be followed for the storage of the instrument Avoid environments with excessive humidity and those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatib...

Страница 3: ...ment can count in absolute mode or relative mode by pressing the corresponding button Also it is possible to set a preset value which can be activated by pressing the corresponding button The electronics are seated in a smart and strong black anodized aluminum case The display can be fixed quickly and easily using the two holes on the housing The unit is powered by a AA 3 6V battery which lasts ap...

Страница 4: ...layed reset after 3s 8 Not active Not active Delayed preset after 3s Delayed means that to activate the function reset or preset it is necessary to keep ENTER RESET pressed for approximately 3 s Reset reset function of the displayed value after pressing ENTER RESET the displayed value is set to zero Preset preset function of the displayed value after pressing ENTER RESET the displayed value become...

Страница 5: ...e Count direction Set out the count direction of the display range allowed 0 or 1 Adjustment of displayed value After the installation of instrument on the machine and setting of all parameters in order to visualize on the display the correct value it is necessary to carry out the reset or preset Position the shaft in a point in which the correct measure that has to be visualized is known exactly ...

Страница 6: ...offset 8 Indicator of negative Offset indicates that the measure is corrected by a negative offset 9 Indicator of values changing it blinks during the programming phase 10 Indicator of origins indicates that the origin changing mode is opened 11 Indicator for origin 1 12 Indicator for origin 2 Error message RX U RX U RX U RX U the current displayed value passed the maximum value that can be visual...

Страница 7: ...lute incremental value mm inch conversion 3 distinct origins for tool changing Protection degree IP54 Display house alluminium black Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43016 San Pancrazio Parma Italy Tel 39 0521 672 34...

Отзывы: