Hollow shaft display
EP9L
Data: 06/11/18
EP9L_ing.doc
pag 3/7
• The configurations provided in the manual are the only ones permitted.
• Do not try to use it anyway contrary to the indications provided.
• The instructions in this manual do not substitute but accomplish the obligations of the current
legislation regarding the safety laws.
Installation
Before installing the instrument, read the following warnings:
a) Connect the instrument strictly following the instructions of the manual.
b) It is the responsibility of the user to check, before using, the correct settings of the parameters
of the instrument to avoid damage to persons or things.
c) The instrument CANNOT function in a dangerous environment (inflammable or explosive).
d) The unit has sensible parts to electrostatic charge, therefore the handling of the inner electronic
cards has to be carried out with appropriate care to avoid permanent damages.
Description
The electronic position indicator EP9L, with inner battery supply, includes in the same case a
position transducer and a display unit setting up a device for measuring linear or angular shifting,
compact, easy assembling, applicable in several type of industry (packaging, woodworking,
aluminium, sheet metal, etc.)
The display has five digits plus sign (range from -99999 up to +99999). The digits are 10mm high
to allow excellent readability also at a distance.
It is possible to select the counting direction, the number of decimal places, and the units (mm or
inches). The displayed value can be corrected with a multiplication factor, with values between
0,0001 and 99999.
The instrument can count in absolute mode or relative mode by pressing the corresponding
button. Also, it is possible to set a preset value which can be activated by pressing the
corresponding button.
The electronics are seated in a smart and strong black anodized aluminum case.
The display can be fixed quickly and easily using the two holes on the housing.
The unit is powered by a ½AA 3.6V battery which lasts approximately 4 years and when the
battery is almost exhausted, an icon will appear to advise the operator to substitute it. This does
not effect the configuration parameters and also the correct measurement is maintained if the
magnetic band is not moved during this operation.
Programming
To step into the parameter programming press key and on the display appears
, now
press 2 times key
RESET
and appear 4 zeroes, the first on the right is blinking, with keys (digit
increase) and
(digit selection), set out password
0273
and confirm with
RESET
. In case of
wrong set-out of password it goes out of the programming. The parameters that have to be set
can be run with key and in order of appearance they are:
0
0
0
0
value to be displayed for every turn of the shaft,
+%
+%
+%
+%
number of decimal digits,
//
//
//
//
keys opening mode
%.+
%.+
%.+
%.+
count direction,
To enter into the modification of the selected parameter press two times
RESET
(one time displays
only the value) and with keys and
set the wanted value to be confirmed with
RESET
.
To go out of the programming press
.
0
0
0
0
value to be displayed for every turn of the shaft
This parameter together with the following one allows to programme the value which has to be
displayed for every turn of the hollow shaft. The range allowed is from 0,0001 to 99999 with setting
of decimal point position that is, after programming of the last digit on the left, pressing key
will