FIAMA EP9L Скачать руководство пользователя страница 3

Hollow shaft display

EP9L

Data: 06/11/18

EP9L_ing.doc

pag 3/7

• The configurations provided in the manual are the only ones permitted.
• Do not try to use it anyway contrary to the indications provided.
• The instructions in this manual do not substitute but accomplish the obligations of the current
legislation regarding the safety laws.

Installation

Before installing the instrument, read the following warnings:
a) Connect the instrument strictly following the instructions of the manual.
b) It is the responsibility of the user to check, before using, the correct settings of the parameters

of the instrument to avoid damage to persons or things.

c) The instrument CANNOT function in a dangerous environment (inflammable or explosive).
d) The unit has sensible parts to electrostatic charge, therefore the handling of the inner electronic

cards has to be carried out with appropriate care to avoid permanent damages.

Description

The electronic position indicator EP9L, with inner battery supply, includes in the same case a
position transducer and a display unit setting up a device for measuring linear or angular shifting,
compact, easy assembling, applicable in several type of industry (packaging, woodworking,
aluminium, sheet metal, etc.)
The display has five digits plus sign (range from -99999 up to +99999). The digits are 10mm high
to allow excellent readability also at a distance.
It is possible to select the counting direction, the number of decimal places, and the units (mm or
inches).  The displayed value can be corrected with a multiplication factor, with values between
0,0001 and 99999.
The instrument can count in absolute mode or relative mode by pressing the corresponding
button. Also, it is possible to set a preset value which can be activated by pressing the
corresponding button.
The electronics are seated in a smart and strong black anodized aluminum case.
The display can be fixed quickly and easily using the two holes on the housing.
The unit is powered by a ½AA 3.6V battery which lasts approximately 4 years and when the
battery is almost exhausted, an icon will appear to advise the operator to substitute it. This does
not effect the configuration parameters and also the correct measurement is maintained if the
magnetic band is not moved during this operation.

Programming

To step into the parameter programming press key     and on the display appears  

, now

press 2 times key 

RESET

 and appear 4 zeroes, the first on the right is blinking, with keys   (digit

increase) and  

 (digit selection), set out password 

0273 

and confirm with 

RESET

. In case of

wrong set-out of password  it goes out of the programming. The parameters that have to be set
can be run with key   and in order of appearance they are:

0

0

0

0

value to be displayed for every turn of the shaft,

+%

+%

+%

+%

number of decimal digits,

//

//

//

//

keys opening mode

%.+

%.+

%.+

%.+

count direction,

To enter into the modification of the selected parameter press two times 

RESET

 (one time displays

only the value) and with keys    and  

 set the wanted value to be confirmed with 

RESET

.

 To go out of the programming press 

  .

0

0

0

0

 

value to be displayed for every turn of the shaft

This parameter together with the following one allows to programme the value which has to be
displayed for every turn of the hollow shaft. The range allowed is from 0,0001 to 99999 with setting
of decimal point position that is, after programming of the last digit on the left, pressing key 

  will

Содержание EP9L

Страница 1: ...Hollow shaft display EP9L Data 06 11 18 EP9L_ing doc pag 1 7 USER S MANUAL AND MAINTENANCE ELECTRONIC HOLLOW SHAFT DISPLAY BATTERY SUPPLIED TYPE EP9L ...

Страница 2: ...ow are some references to be followed for the storage of the instrument Avoid environments with excessive humidity and those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatib...

Страница 3: ...ment can count in absolute mode or relative mode by pressing the corresponding button Also it is possible to set a preset value which can be activated by pressing the corresponding button The electronics are seated in a smart and strong black anodized aluminum case The display can be fixed quickly and easily using the two holes on the housing The unit is powered by a AA 3 6V battery which lasts ap...

Страница 4: ...layed reset after 3s 8 Not active Not active Delayed preset after 3s Delayed means that to activate the function reset or preset it is necessary to keep ENTER RESET pressed for approximately 3 s Reset reset function of the displayed value after pressing ENTER RESET the displayed value is set to zero Preset preset function of the displayed value after pressing ENTER RESET the displayed value become...

Страница 5: ...e Count direction Set out the count direction of the display range allowed 0 or 1 Adjustment of displayed value After the installation of instrument on the machine and setting of all parameters in order to visualize on the display the correct value it is necessary to carry out the reset or preset Position the shaft in a point in which the correct measure that has to be visualized is known exactly ...

Страница 6: ...offset 8 Indicator of negative Offset indicates that the measure is corrected by a negative offset 9 Indicator of values changing it blinks during the programming phase 10 Indicator of origins indicates that the origin changing mode is opened 11 Indicator for origin 1 12 Indicator for origin 2 Error message RX U RX U RX U RX U the current displayed value passed the maximum value that can be visual...

Страница 7: ...lute incremental value mm inch conversion 3 distinct origins for tool changing Protection degree IP54 Display house alluminium black Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43016 San Pancrazio Parma Italy Tel 39 0521 672 34...

Отзывы: