Hollow shaft display

EP9L

Data: 06/11/18

EP9L_ing.doc

pag 1/7

USER’S MANUAL AND MAINTENANCE

ELECTRONIC HOLLOW SHAFT DISPLAY

BATTERY SUPPLIED TYPE “EP9L-“

Содержание EP9L

Страница 1: ...Hollow shaft display EP9L Data 06 11 18 EP9L_ing doc pag 1 7 USER S MANUAL AND MAINTENANCE ELECTRONIC HOLLOW SHAFT DISPLAY BATTERY SUPPLIED TYPE EP9L ...

Страница 2: ...ow are some references to be followed for the storage of the instrument Avoid environments with excessive humidity and those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatib...

Страница 3: ...ment can count in absolute mode or relative mode by pressing the corresponding button Also it is possible to set a preset value which can be activated by pressing the corresponding button The electronics are seated in a smart and strong black anodized aluminum case The display can be fixed quickly and easily using the two holes on the housing The unit is powered by a AA 3 6V battery which lasts ap...

Страница 4: ...layed reset after 3s 8 Not active Not active Delayed preset after 3s Delayed means that to activate the function reset or preset it is necessary to keep ENTER RESET pressed for approximately 3 s Reset reset function of the displayed value after pressing ENTER RESET the displayed value is set to zero Preset preset function of the displayed value after pressing ENTER RESET the displayed value become...

Страница 5: ...e Count direction Set out the count direction of the display range allowed 0 or 1 Adjustment of displayed value After the installation of instrument on the machine and setting of all parameters in order to visualize on the display the correct value it is necessary to carry out the reset or preset Position the shaft in a point in which the correct measure that has to be visualized is known exactly ...

Страница 6: ...offset 8 Indicator of negative Offset indicates that the measure is corrected by a negative offset 9 Indicator of values changing it blinks during the programming phase 10 Indicator of origins indicates that the origin changing mode is opened 11 Indicator for origin 1 12 Indicator for origin 2 Error message RX U RX U RX U RX U the current displayed value passed the maximum value that can be visual...

Страница 7: ...lute incremental value mm inch conversion 3 distinct origins for tool changing Protection degree IP54 Display house alluminium black Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43016 San Pancrazio Parma Italy Tel 39 0521 672 34...

Отзывы: