52
53
2.10 Installation niche features:
Brilliance-Classic Series
A
- area to be left clear for the anti-tipping brackets
E
- area to be left clear for the power supply cable
W
- and water supply hose
Minimum Niche Height
2064 mm (81 1/4”)
Minimum Niche Width
BKI899: 900 mm (35 1/2”)
BKI749: 750 mm (29 5/8”)
BKI599: 600 mm (23 3/4”)
Minimum Niche Depth
615 mm (24 1/4”)
Door Swing Clearance
BKI899: 1435 mm (56 1/2” in)
BKI749: 1285 mm (50 5/8” in)
BKI599: 1135 mm (44 3/4” in)
Door Opening Angle
105°
Width
BKI899: 899 mm (35 3/8”)
BKI749: 749 mm (29 1/2”)
BKI599: 599 mm (23 5/8”)
Height
2050 mm (80 3/4”) + 25 mm (1”)
Depth with door
600 mm (23 3/4” in)
Minimum distance from the wall (hinge side)
BKI899: 230 mm (9”)
BKI749: 195 mm (7 3/4”)
BKI599: 160 mm (6 1/4”)
Dimensions in parentheses
are in inches.
2. TECHNICAL REQUIREMENTS
www.fhiaba.com · [email protected] · Info Line +39 0434 420160
3.1 Transport to installation site
and unpacking
The appliance is very heavy.
Take maximum care during handling
to avoid injury.
The appliance should always be
transported in an erect position.
Avoid at all costs leaning it on its front
side.
Since this is a large and heavy appliance, before trans-
porting the appliance, check the access to the loca-
tion where it will be installed (door size, manoeuvring
space in stairwells, etc.).
The appliance is attached to the base of the packaging
(pallet) through four bolts which can be removed us-
ing a 17 mm (3/4”) wrench.
It is recommended to use a manual transporting de-
vice to move the appliance to the installation site, and
only at this point to remove the base of the packaging.
The appliance should always be transported in an
erect position.
If this is not possible, transport the appliance laying
on its rear side.
Once at the installation site, the appliance, which is
equipped with four wheels, can be taken off the pallet
and positioned in the installation area.
Operate as follows:
>
Take off the four boltshsecuring the appliance to the
pallet by means of a 17 mm (3/4”) open spanner.
>
Remove the fixing brackets
[ 3 ]
and
[ 4 ]
.
>
To remove the front fixing bracket
[ 3 ]
, unscrew for
one or two turns the rear wheel adjusting bolt
[ 2 ]
by
means of a 13 mm (1/2”) box spanner, avoiding too
much strenght while thightening the nut, which could
damage the leveling feet adjusting system.
>
From the back of the unit and by means of a suit-
able, high duty hand trolley, take off the appliance and
place it on the floor.
Be very careful to avoid any damage to floors. Delicate
floors should be protected with plywood, hard card-
board or similar material panels.
3. PREPARING THE INSTALLATION
3.2 Electrical and Water connection
The Built-in Fhiaba filter cannot make it
safe to drink any water which is not suit-
able for human consumption.
The appliance should be connected only
to a drinkable water supply system.
Do not use extension cords or adapters.
Once the appliance has been connected to
the water system, turn the Ice Maker
off (touch the button
on control panel
to switch it off) before the main water is
shut off.
A Schuko 16 A socket with an efficient grounding
should be made available for the electrical mains con-
nection, as well as an omnipolar
switch which can easily be reached when the appli-
ance is installed.
To connect to the water supply system (for appliances
equipped with ice makers) a tap with a male 3/4” con-
nection should be provided, which must also be easily
accessible once the appliance is installed.
The appliance is provided with a water supply hose
and seal kit which is suitable for high water pressure
and complies the Food Regulations.
The water filter cartridge, which is provided with the
appliance, should be installed according to the ac-
companying instructions.
Use only the new hose and the new gaskets which
are supplied with the appliance. Discard any hose and
gasket which may have already been installed.
Electrical cord length: 2,0 mt (78 3/4”)
Water connection line length: 2,5 mt (98 3/8”)
www.fhiaba.com · [email protected] · Info Line +39 0434 420160
EN
A
A
E
W
E
W
140 (5 ½”)
140 (5 ½”)
100 (4”)
100 (4”)
min 2064 (81 ¼”)
BKI899: 900 (35 ½”)
BKI599: 600 (23 ¾”)
BKI749: 750 (29 ⅝”)
600 (23 ¾”)
525 (20
⅝”
)
0T
693 (27
¼”
)
2050 (80
¾
”) +25 (1”)
1308 (51
½”
)
587 (23
⅛”
)
146 (5
¾”
)
+ 25(1”)
9 (
⅜”
)
732 (28 ⅞
”)+25 (1”)
105°
BKI899: 1435 (56 ½”)
BKI749: 1285 (50
⅝
”)
BKI599: 1135 (44
¾
”)
525 (20
⅝
”)
600 (23
¾
”)
BKI899: 899 (35 ⅜”)
BKI749: 749 (29 ½”)
BKI599: 599 (23 ⅝”)
10 (
⅜
”)
75 (3”)
58 (2 ¼”)
BKI899: 230 (9”)
BKI749: 195 (7 ¾”)
BKI599: 160 (6 ¼”)
1
4
1
2
3
E
W
E
W
E
W
E
W