21
SIP Authentication
Here
Username
and
Password
can be set for the SIP-Registration.
SIP Register Settings
There are two
IP addresses
for registration configurable. The Parameter
"Secondary PBX"
is only used however if
"PBX Alternation enabled"
is
selected further down on the webpage.
With
"SIP Port"
a port can be set between 5.000 and 31.000 for the SIP
connection.
"Register Attempts"
specifies the number of registration attempts before
the telephone gives up trying to register. A value of zero corresponds to an in-
finite number of attempts.
"Repeat Register Attempt After [secs]"
indicates the time in seconds that
passes after each failed attempt before the telephone makes another attempt.
The parameter
"Register Expire"
defines the expire value the telephone us-
es for a registration attempt at the PBX. The value is limited to a range of 60
to 3600 seconds. The value will be used initially. If the PBX accepts the regis-
tration, then the telephone adapts the parameter with the value in the re-
ceived [ACK] message. If a PBX rejects the register request with an answer
containing "Interval too brief" as a reason, the phone will not be registered.
The register expire value negotiated with the PBX will be used to check the
connection with the PBX. If registering to the second PBX
("PBX Alterna-
tion"
=
"enabled"
) the configured value in the field
"Register Expire"
will
be used initially.
SIP Features
"Interdigit timer [ms]"
defines the duration in ms the telephone is waiting
between two key strokes before trying to make a call with the already entered
digits.
"Idle timer [ms]"
defines the time the phone is waiting after lifting the
handset, to switch to the next state. This takes the field
"Auto dialer"
in ac-
count. If this option not is active, then the next state is an error state. If this
option is active, then dialling will be started with the number from the field
"Auto dialer Number"
. This field must not be empty with activated auto
dialer. The user has to take care for the configured data. If a call is made with
the auto dialer, then the number will not be stored in the redial memory.
Содержание InduTel IP
Страница 1: ...IP Weatherproof telephone FHF BA 9605 05 09 16 V1 Operating instructions...
Страница 13: ...13 2 4 Dimensions Figure 6 Dimensions in mm...
Страница 23: ...23 Figure 11 SIP Settings...
Страница 30: ...30 Figure 17 Reset Settings...
Страница 45: ...45 Degree of protection in accordance with IEC60529 IP 66 closed...
Страница 47: ......