Page 8
Manual ExResistTel
IP2
1.4.3
LAN Interface 10/100 BASE-TX according to IEEE 802.3
(not intrinsically safe)
Terminal no.: 8, 9, 10, 13
U
n
= ±2.5 V (10 BASE-TX)
respectively
U
n
= ±1 V (100 BASE-TX)
U
m
= ±7 V
U
m
= DC 57 V
For the LAN connection it is only allowed to use cables of the type CAT5e or higher.
To observe the EMC rules with netting shielded cables have to be used.
1.4.4
Potential-free Relay Contacts (not intrinsically safe)
Terminal no.: 18, 20 respectively no.: 21, 23
•
U
max
= AC 250 V
I
max
= 5 A
P
max
= 100 VA
For this connection cables with a transversal section of 1.5 mm² to 4 mm² are
allowed to be used only.
•
U
max
= DC 230 V
I
max
= 0.5 A
P
max
= 100 W
For this connection cables with a transversal section of 0.75 mm² to 4 mm²
are allowed to be used only.
Содержание ExResistTel IP2
Страница 1: ...Explosion proof VoIP telephone Operating instructions FHF BA 9711 03 13...
Страница 22: ...Page 22 Manual ExResistTel IP2 4 Declarations and Approvals 4 1 EC Type Examination Certificate ExResistTel IP2...
Страница 23: ...Manual ExResistTel IP2 Page 23...
Страница 24: ...Page 24 Manual ExResistTel IP2...
Страница 26: ...Page 26 Manual ExResistTel IP2 4 3 Declaration of Conformity ExResistTel IP2...
Страница 27: ...Manual ExResistTel IP2 Page 27...