Page 6
Manual ExResistTel
IP2
Note
The installation prescribed in the regulations according to IEC/EN 60079-14 and the
national installation regulations have to be respected.
1.3
Construction
1.3.1
Housing
The telephone type ExResistTel IP2 has a non coloured housing made of an
electrostatic conductive pressed basic material and a stainless steel keypad.
Optionally the housing can be coloured with an electrostatic conductive colour.
In the front plate of the keypad is a display cut-out closed with a viewing glass.
The housing consists of a box-shaped bottom part with a tray for inserting the
electronic and a curved top cover with a keypad.
The top cover will be pressed with four screws to the upper part with in between a
revolving seal and generates the intrinsically safe as well as the non-intrinsically safe
terminal compartment. In the tray is a grouting cup with the embedded electronic.
1.3.2
Configuration Plug Connector
A 6 pin plug connector sticks out of the grouting tray inside the telephone (14).
The configuration plug connector will be used by the manufacturer of the telephone
type ExResistTel IP2 for configuration only and must not be connected.
The programming by the installer is not allowed.
1.3.3
Intrinsically Safe Keypad Connection
An intrinsically safe 14-terminal ribbon cable with a female plug will be carried out of
the grouting tray inside the telephone.
The female plug has to be plugged to the 14 pin plug connector in the upper part of
the housing securely, before the telephone will be screwed down.
Содержание ExResistTel IP2
Страница 1: ...Explosion proof VoIP telephone Operating instructions FHF BA 9711 03 13...
Страница 22: ...Page 22 Manual ExResistTel IP2 4 Declarations and Approvals 4 1 EC Type Examination Certificate ExResistTel IP2...
Страница 23: ...Manual ExResistTel IP2 Page 23...
Страница 24: ...Page 24 Manual ExResistTel IP2...
Страница 26: ...Page 26 Manual ExResistTel IP2 4 3 Declaration of Conformity ExResistTel IP2...
Страница 27: ...Manual ExResistTel IP2 Page 27...