SLM1: Quick Reference – Rev06
Page 7/9
Door1 selected
Door2 selected
Door3 selected
Door4 selected
Door5 selected
Door6 selected
4
Check of activation
sources
(Option1 sensors or
Option2 pedals)
Press the button
on the control unit panel for 5s to exit the Inspection
mode set in the previous step.
Acting in sequence on all the connected activation sources and verify that
the panels open correctly. After every activation, wait for the conclusion of
the opening and closing processes.
Views:
(Ready)
Always ON
(Closed)
ON when ALL the doors are closed
(Opened)
ON when at least one door is completely
open
5
Check of obstacle
during opening process
Acting in sequence on all the connected activation sources and stop the
opening movement of the panels.
When the related driver recognizes the obstacle, there is an inversion of
20mm + 2s pause, to let the obstacle to be removed. Remove the obstacle.
Wait for the conclusion of the opening and closing processes before acting
on the following panel.
Views:
(Obstacle)
ON during inversion
6
Check of obstacle
during closing process
Acting in sequence on all the connected activation sources and stop the
opening movement of the panels.
When the related driver recognizes the obstacle, there is a complete
inversion to let the obstacle to be removed. After a pre-defined time the
panel closes. Wait for the conclusion of the re-opening and closing processes
before acting on the following panel.
(Obstacle)
ON during re-opening process