background image

10

Track Interrupt Mode <spi prefix> + <069> ; <mode>

Enable/Disable play track interrupt

default

130069

interrogate

1300690

no interrupt

1300691

DTMF interrupt

1300692

COS interrupt

There are three interrupt modes available on the FF-8070:
RESPONSE

DESCRIPTION

"I N T Cancel"

<mode> = 0, No interrupt allowed -- all tracks will play to completion

"I N T D T M F"

<mode> = 1, Only interrupt if a DTMF digit is detected

"I N T C O S"

<mode> = 2, Interrupt if DTMF or COS detected during play

These modes allow the user to set the play interrupt mode for their DVR.  <mode> = 1 is most
generally recommended for users who do not want COS interrupt of DVR tracks because it still
allows an interrupt mechanism that is available (pressing a DTMF digit) to terminate a track play if
desired.

Save Config. Flags

<spi prefix> + <067800>

Set configuration flags to EEPROM

default

130067800

This command "saves" the status of the configuration flags register.  On reset, this register is
recalled from EEPROM so that the contents can continue to reflect the user's desired setting.  The
configuration flags save the Blank annunciate flag and the interrupt mode.  Changes made to these
settings will not be retained until saved with this command.  Also, the auto erase time is saved with
this command.

Clear Mail Codes

<spi prefix> + <0581800> Clear mail suffixes

default

1300581800

This command should be executed anytime that the voice mail command codes are to be changed.  This
resets the function codes to the factory defaults which can help reduce difficulties that may be encountered
with the FF-8070 code checking procedure.

Auto Play delay

<spi prefix> + <0580> ; <t>

Set or interrogate the auto play delay

default

1300580t

This command is used to set the auto play delay from <t> = 0 to 9 minutes.  The auto play delay
affects tracks 100 and 101 and prevents them from being played if a user enters the "List active
messages" command within the time set by this command.  The factory default is 3 minutes.

Auto Erase delay

<spi prefix> + <0582> ; <t>

Set or interrogate the auto erase delay

default

1300582t

This command is used to set the auto erase delay from <t> = 0 to 255 hours.  The auto erase time
is attached to each voice mail message when it is recorded.  When the time expires, the message is
automatically erased.  <t> = 0 hours disables the auto erase feature -- the factory default time is 255
hours, or a little over 10 days.  This parameter must be saved using the Save Config. Flags
command.

FF-800 Interface Programming

The FF-800 allows any of the system tracks to be entered into speech messages on the FF-800 via the
"[SPI]" speech phrase macro (word# 182).  When the message is processed by the FF-800, the

Содержание FF-8070

Страница 1: ...FF 8070 Operations Manual Digital Voice Recorder Revised December 14 2002 Copyright FF Systems 2001 2002 All Rights Reserved...

Страница 2: ...e of Contents Warranty 1 Introduction 2 Operation Overview 2 Installation 3 DVR Functions 3 User Commands 4 Configuration Commands 7 FF 800 Interface Programming 10 FF 8070 Command Examples 11 Adjustm...

Страница 3: ...ays after shipment from FF Systems If the purchaser decides to return a product they must contact FF Systems for a Return Material Authorization RMA number on or before 6 00pm central time within 35 c...

Страница 4: ...stream is stored on 1 megabit DRAMS each of which can hold about 20 seconds of sampled audio The FF 8070 comes standard with 8 one megabit DRAMS with room for additional memory up to a maximum total...

Страница 5: ...user reference The battery input P2 should be connected to a battery for maintaining DVR operation during power interruptions The battery must be greater than 9 volts accross its discharge cycle and l...

Страница 6: ...e DESCRIPTION 00 Play system track 01 Record system track 01 Interrogate system track size 02 Set input source Selects main or aux phone patch DVR input 03 System track erase 040 Search system track s...

Страница 7: ...al or any DTMF digit if input aux to begin recording on the test track After the loss of COS or another DTMF digit if input aux the test track is played back The maximum record time for the test track...

Страница 8: ...ges is erased Also there is a time out limit of 5 seconds after each prompt if no COS is engaged within this time the mailbox operation is aborted To query the mail box the list active messages comman...

Страница 9: ...must be installed to set the security code Record system track spi prefix 01nn Record track nn spi prefix 01 nn Interrogate track length spi prefix 07nn Record no play back default 13001nn record 1300...

Страница 10: ...ng function plays each track in its entirety while the search short only plays the first 1 second of each track LOPSTART A spi prefix 050 nnn Start lop off input A milliseconds LOPEND A spi prefix 051...

Страница 11: ...for system tracks and mailbox tracks If this balance is difficult to achieve then it may be necessary to add more memory Set User Defined Prefixes Set Audio Test suffix spi prefix 054d d Set List act...

Страница 12: ...time is saved with this command Clear Mail Codes spi prefix 0581800 Clear mail suffixes default 1300581800 This command should be executed anytime that the voice mail command codes are to be changed T...

Страница 13: ...hen this phrase macro would be omitted A sequence suitable for a tail message is as follows MES 10 SPI 6 101 SPI 6 101 This will play track 02 if there are any mail box messages and can be assigned to...

Страница 14: ...00537 response Set M T Three Set lop values 130017 record a test track response D V R after track is recorded the 8070 will replay to verify 130051200 set lop end to 200ms 0 2 sec response Set Stop Tw...

Страница 15: ...x input level VR2 is slightly more difficult to adjust since the DVR audio is redirected to the phone during a control autopatch Also if a second telephone is not available at the repeater site anothe...

Страница 16: ...1 or 2 inches of hookup wire to the shield as shown above and cut off the remainder of the shield Cut this wire even with the others and trim 0 1 of insulation from the end of each wire Using a pair...

Страница 17: ...e recording tracks because each reallocated track is erased in the process The allocation data is stored in nonvolitile memory which is specified to maintain data for up to 10 years Thus if the DVR lo...

Страница 18: ...t SMD resistor 1206 type package VR1 2 10K potentiometer RP1 4 1 5K x 9 resistor pack common bus RP5 6 10K x 5 resistor pack common bus D1 2 6 1N4001 Diode 50PIV D7 1N4735 6 2 V zener diode 1 2 watt Q...

Страница 19: ...FF 8070 Component Layout...

Страница 20: ...18 19 20 21 22 23 24 25 26 27 15 17 14 13 12 11 16 4 U43 G A 1 A 2 A 3 A 4 Y1 Y2 Y3 Y4 G A 5 A 6 A 7 A 8 Y5 Y6 Y7 Y8 19 2 17 4 15 18 3 16 5 1 6 13 8 11 14 7 12 9 74HC244 U41 G A 1 A 2 A 3 A 4 Y1 Y2 Y...

Страница 21: ...PORT D W A9 R A8 A0 A7 A1 A6 A2 A5 A3 A4 REFCAS CAS3 BNK0 CAS2 BNK1 CAS0 BNK2 CAS1 BNK3 5V MEMBUS MOSI SPCK MISO RST1 SELP0 SELP1 IOA IOB IOC IOD DVRo RQ0 RQ1 RQ2 RQ3 MPT 5V 5V 6 5 7 b U47 LF353N R8 1...

Страница 22: ...5 6 7 8 9 10 1 1 5Kx9 RP1 CAS00 CAS01 CAS02 CAS03 CAS04 CAS05 CAS06 CAS07 BNK0 BNK1 BNK2 BK3b BK3a G A 1 A 2 A 3 A 4 Y1 Y2 Y3 Y4 G A 5 A 6 A 7 A 8 Y5 Y6 Y7 Y8 19 2 17 4 15 18 3 16 5 1 6 13 8 11 14 7 1...

Страница 23: ...6 7 8 9 10 1 RP3 1 5Kx9 CAS20 CAS21 CAS22 CAS23 CAS24 CAS25 CAS26 CAS27 BNK0 BNK1 BNK2 BK3b BK3a G A 1 A 2 A 3 A 4 Y1 Y2 Y3 Y4 G A 5 A 6 A 7 A 8 Y5 Y6 Y7 Y8 19 2 17 4 15 18 3 16 5 1 6 13 8 11 14 7 12...

Страница 24: ...he center of the power audio cable The end of this wire has a molex crimp pin installed with a short section of heat shrink tubing to prevent it from shorting to adjacent circuitry This wire can eithe...

Страница 25: ...The battery backup cable provides a DB 9 connection for an external battery DB 9 pinout 1 BATT 8 12V 2 n c 3 n c 4 n c 5 n c 6 BATT 7 BATT 8 BATT 9 BATT...

Отзывы: