7
2
1
3
TO REMOVE:
Pull silicone
tap guard
down
1) To access setting controls
Open the cover panel
Correction for altitude
To access controls
1) Remove lower face panel first,
2) Upper face panel next,
3) Top panel last
Access the dials of the three rotary switches
Dials are marked
S3 TH (temperature)
S2 time(
x
) 1
S1 time(
x
) 10
}
(portion)
To access rotary switches for adjusting
-Turn off power
-Remove covers to access dials for setting
temperature and dispense volume
-Remove all screws and panels to access control
board for adjustments.
-Pull off silicone tap guard
Reinstall and tighten all screws before power-up
Do not operate without all covers and screws in
place.
Reinstall covers
-Reverse steps 1-3 (above)
Altitude Boiling
Point
(ft) (m) (
o
f) (
o
c)
-250 -76 212.5
100.3
0 0
212
100
500 152 211 99.5
1000 305 210.1 98.9
1500 457 209.1 98.4
2000 610 208.1 97.8
2500 762 207.2 97.3
3000 914 206.2 96.8
3500 1067 205.3 96.3
4000 1219 204.3 95.7
4500 1372 203.4 95.2
5000 1524 202.4 94.7
5500 1676 201.5 94.2
6000 1829 200.6 93.6
6500 1981 199.6 93.1
7000 2134 198.7 92.6
2) To set water portion and temperature controls
Setting Dispense Volume
Setting Dispense Temperature
Upper dial
Temperature
Setting
Deg. C Deg.
F
0
87 189
1
88 190
2
89 192
3
90 194
Lower Dials
(Marked S1 &S2 )
Set dispense volume
The two lower dials control the hot water
volume to be delivered by setting the dispense
time in seconds.
The timer dials are additive and control flow for
1 to 30 seconds or approximately 40-1200ml
(1.3-40.6 fluid ounces.)
36-42 ml/1.2-1.4oz is dispensed in 1 second.
4
91 196
Dial Settings for Dispense Volume
5
92 197
Bottom
Top Sec ml
oz
6
93 199
0+ 0= 1
40 1.4
7
94 201
0+ 1= 1
40 1.4
8
95 203
0+ 5= 5
200 6.8
9
96 205
0+ 6= 6
240 8.1
1+ 5= 15
600 20.3
Above is an example at typical 45 psi/310kPa
water pressure.
Actual volume delivered is affected by flow rate
(the supply water line pressure). Lower water
pressure or pressure drops may lower flow rate.
Higher pressure will increase flow rate.
Unit is factory set at 5 seconds=200ml/6.8oz.
Temperature setting (upper)
Upper Dial (
Marked: S3
)
Set temperature
Base temperature begins at
87°C/189°F, in Celsius units.
Add dial position numerical value in
degrees Celsius (°C) to 90° base to a
maximum of 96°C/205°F
Unit is factory set at
96°C/205°F
.
Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice
TEMPERATURE SETTING DIAL
Posit
ions 4-9 are inact
ive
1
2
3
4
5
6
7
8
9
0
1
3
4
5
6
7
8
9
0
PORTION
S1 S2
PORTION CONTROLSETTING DIALS
1
2
3
4
6
7
8
9
0
S3 TH
Volume setting (two lower)
2