Installation 

 

 

The installation must comply with applicable federal, state, and local codes having jurisdiction at your location. Utilize only 
qualified beverage equipment service technicians for installation. 
A Service Company Directory may be found on our website, 

http://www.fetco.com

 

 
 
 
Setup  

 

1.  Before placing the unit, verify that it will fit in the space intended for it, and that 

the counter or table will support its’ weight. 

2.   When the unit is in position, use a bubble level to level it front to back and side 

to side by adjusting the legs. 

 

 
Water Connection 

 

1.  Water inlet is ¼  inch flare fitting. 
2.  Install a shut off valve near the unit to facilitate service. 
3.  Install a backflow prevention device, a spring loaded double check valve such 

as a WATTS SD-2 or SD-3 is usually accepted by most zoning authorities. 

4.  If an inline water filter is used (highly recommended), it should be installed after 

the water shut off valve and in a position to facilitate filter replacement. 

5.  Flush the water supply line and filter 

before

 connecting it to the unit. 

6.  Verify that the water line provides at least 1½ gpm (5.7lpm), and that the water  

pressure is between 20-75 psig (138-517 kPa)  

 

 
Cleaning & Maintenance 

 

Daily:  

1.  Check the drip tray and empty if necessary. 

 

Quarterly:  

1.  Inspect all fittings and hoses for leaks. 
2.  Inspect inside of tank for lime deposits. De-lime tank and probes if necessary.  
3.  (This procedure to be performed by a qualified service technician) 

 

Notice:  

1.  Turn off power before any cleaning procedure, including wiping the exterior for appearance reasons.   
     Dry the exterior, especially the face panel, before turning on power. 

 

WARNING:  

1.  Equipment is designed for commercial use only.  Equipment is not for household use. 
2.  Do not apply any type of spray cleaner on the face panel of this equipment. 
3.  Never use solvent or solvent based cleaner or petroleum based polish on this equipment.  
4.  Dry the face of the HWD-2102 before turning on power. 
5.  No user serviceable parts; refer to qualified service technician for repair and adjustments. 
6.  Dangerous high voltage and high temperatures inside 
7.  WARNING-Do not plug-in this equipment or attempt to operate without all covers in place and all screws fastened 
8.  Unplug machine before disassembly or changing settings 

 
 

 
 
 

Warning: Legs are to be adjusted 
only to level the unit.   Do not extend 
them higher than necessary 

Back panel of HWB-2102

Power 

Switch

 

Water 
Supply 
Inlet

 

 

Electrical  

Connection 

Tank 
Drain

 

Содержание HWB-2102 series

Страница 1: ...ries commercial hot water dispensers Table of Contents Operator and User Section FETCO Hot Water Dispenser HWD_2102 2 Contact Information 2 Description Features 2 Operating Instructions 2 Technical an...

Страница 2: ...lit proper dispense temperature is enabled When heating or reheating the green READY light will turn off and the HEATING light will display Dispense flow rate is given for typical 45psi 0 31mPa water...

Страница 3: ...d Lift finger and reactivate after portion by retouching pad for next dispense portion Finger must be on pad to dispense To dispense for PORTION CONTROL Touch and Hold 1 Press and hold UNLOCK DISPENSE...

Страница 4: ...pe of spray cleaner on the face panel of this equipment 3 Never use solvent or solvent based cleaner or petroleum based polish on this equipment 4 Dry the face of the HWD 2102 before turning on power...

Страница 5: ...sec to maximum single dispense is 1200ml 40 5 ounces in 30seconds maximum dispense time Dimensions Utility Connections Designs materials specifications physical dimensions firmware and software protoc...

Страница 6: ...water pressure is between 20 75 psig 138 517 kPa Cleaning Maintenance Daily 1 Check the drip tray and empty if necessary Quarterly 1 Inspect all fittings and hoses for leaks 2 Inspect inside of tank f...

Страница 7: ...88 190 2 89 192 3 90 194 Lower Dials Marked S1 S2 Set dispense volume The two lower dials control the hot water volume to be delivered by setting the dispense time in seconds The timer dials are addi...

Страница 8: ...ermistor error at once Blink On Off Initial fill error Tank has not filled in 6 minutes Blink On On Fill error Tank does not re fill after 1 minute Blink Blink Off Boil error If the heater is on and T...

Страница 9: ...e Initial Fill Error Tank has not filled in 6 minutes Fill Error Tank does note re fill after 1 minute Boil Error If The heater is on and Tank temperature temperature tank was last off 1 C and Tank te...

Страница 10: ...efore any cleaning procedure including wiping the exterior for appearance reasons Dry the exterior especially the face panel before turning on power WARNING 6 Do not apply any type of spray cleaner on...

Страница 11: ...as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or authorized service personnel with the specified cord on...

Страница 12: ...with capacity rated by local code or National Electrical Code for the current draw of this equipment Check serial number plate on right side for power requirements Locate unit away from source of hea...

Отзывы: