CBS-1241

PLUS

 Single 1 Gallon-3.0-4.0 Liter Coffee Brewers    

Domestic models

 

Electrical and Output Specifications

     

All brewers have factory installed cord and plug  50Hz or 60Hz

 

SKU 

Voltage 

Heater 

Configuration  Wires 

KW 

Electrical 

Connection  Phase  Amp Draw 

Dispense 

Capacity 

E1241US-1A115-PM001 

120 

1 X 1.5 kW 

2+G 

1.5 

NEMA 5-15P 

13.0 

4.0 gal/15.1 L 

E1241US-1A123-PM002 

120 

1 X 2.3 kW 

2+G 

2.3 

NEMA 5-20P 

19.7 

6.1 gal/23.2 L 

CBS-1241

PLUS

 Single 1 Gallon-3.0-4.0 Liter Coffee Brewers      

Field configurable Domestic

 

Electrical and Output Specifications

    

Brewer has factory installed cord and plug & terminal block  50Hz or 60Hz

 

SKU 

Voltage 

Heater 

Configuration  Wires 

KW 

Electrical 

Connection  Phase  Amp Draw 

Brew-Volume 

per hour 

E1241US-1X117-PM001 

120 

1 X 1.7 kW 

2+G 

1.7 

NEMA 15-5P 

14.7 

4.5 gal/17.1 L 

Domestic-Dual Voltage  208-240  2 X 1.7 kW 

2+G  2.6-3.4  Terminal Block 

12.8-14.7  9.0 gal/34.2 L 

CBS-1241

PLUS

 Single 1 Gallon-3.0-4.0 Liter Coffee Brewers      

International models

 

Electrical and Output Specifications     

All brewers have terminal block electrical utility connection  50Hz or 60Hz

 

SKU 

Voltage 

Heater 

Configuration  Wires 

KW 

Electrical 

Connection  Phase  Amp Draw 

Brew-Volume 

per hour 

E1241IN-1B123-PM000  200-240  1 X 2.3 kW 

2+G  1.6-2.3  Terminal Block 

8.5-10.1  6.1 gal/23.2 L 

E1241IN-1B130-PM000  200-240  1 X 3.0 kW 

2+G  2.1-3.0  Terminal Block 

10.9-13.0  8.0 gal/30.2 L 

E1241IN-1B130-MM000  200-240  1 X 3.0 kW 

2+G  2.1-3.0  Terminal Block 

10.9-13.0  8.0 gal/30.2 L 

E1241IN-1B140-PM000  200-240  1 X 4.0 kW 

2+G  2.8-4.0  Terminal Block 

14.9-17.2  10.0 gal/37.9 L 

E1241NM-1B140-PM000  200-240  1 X 4.0 kW 

2+G  2.8-4.0  Terminal Block 

14.9-17.2  10.0 gal/37.9 L 

CBS-1241

PLUS

 Single 1 Gallon-3.0-4.0 Lit er Coffee B rewers      

C E m odels

 

Electrical and Output Specifications     

 Schuko cor d and pl ug two phase 50Hz CE 

SKU  

Voltage 

Heater C onfiguration 

Wires 

KW 

Electrical C onnecti on 

Phase 

Amp Dr aw  

Brew-Volum e per hour 

E1241C E-1B130-PM000 

230 

1  X 3.0 kW  

L/N/PE 

2.8 

EU1- 16P 

12.5 

7.7 gal/29.1 L 

CBS-1241

PLUS

 Single 1 Gallon-3.0-4.0 Liter Coffee Brewers      

Field configurable International

 

Electrical and Output Specifications

    

Brewer has factory installed cord and plug & terminal block  50Hz or 60Hz

 

SKU 

Voltage 

Heater 

Configuration  Wires 

KW 

Electrical 

Connection  Phase  Amp Draw 

Brew-Volume 

per hour 

E1241NM-1X123-PM002 

120 

1 X 2.3 kW 

2+G 

2.3 

NEMA 5-20P 

19.7 

6.1 gal/23.2 L 

Dual Voltage 

120/208-240 

2 X 2.3 kW 

3+G 

4.6  Terminal Block 

17.1-19.7  10.0 gal/37.9 L 

CBS-1242

PLUS

 Dual 1 Gallon-3.0-4.0 Liter Coffee Brewers    

Domestic models

 

Electrical and Output Specifications

     All brewers have terminal block electrical utility connection  50Hz or 60Hz 

SKU 

Voltage 

Heater 

Configuration  Wires 

KW 

Electrical 

Connection  Phase  Amp Draw 

Brew-Volume 

per hour 

E1242US-1B223-PM000  208-240  2 X 2.3 kW 

2+G  3.5-4.6  Terminal Block 

17.1-19.7  12.2 gal/46.3 L 

E1242US-1B230-PM000  208-240  2 X 3.0 kW 

2+G  4.5-6.0  Terminal Block 

22.2-25.5  15.9 gal/54 L 

E1242US-1B230-MM000  208-240  2 X 3.0 kW 

2+G  4.5-6.0  Terminal Block 

22.2-25.5  15.9 gal/54 L 

CBS-1242

PLUS

 Dual 1 Gallon-3.0-4.0 Liter Coffee Brewers    

International models

 

Electrical and Output Specifications

     All brewers have terminal block electrical utility connection  50Hz or 60Hz 

SKU 

Voltage 

Heater 

Configuration  Wires 

KW 

Electrical 

Connection  Phase  Amp Draw 

Brew-Volume 

per hour 

E1242IN-1B223-PM000  200-240  2 X 2.3 kW 

2+G  3.2-4.6  Terminal Block 

16.5-19.7  12.2 gal/46.3 L 

E1242IN-1B230-PM000  200-240  2 X 3.0 kW 

2+G  4.2-6.0  Terminal Block 

21.3-25.5  15.9 gal/60.4 L 

E1242NM-1B230-PM000  200-240  2 X 3.0 kW 

2+G  4.2-6.0  Terminal Block 

21.3-25.5  15.9 gal/60.4 L 

CBS-1242

PLU S

 Dual 1 Gallon- 3.0-4.0 Liter Coffee Brewers   

CE model s

 

Electrical and Output Specifications

     All br ewers have terminal block el ectrical utility connection 230volt/50H z 

SKU  

Voltage 

Heater C onfiguration 

Wires 

KW 

Electrical C onnecti on 

Phase 

Amp Dr aw  

Brew-Volum e per hour 

E1242C E-1B230-PM000* 

230 

2  X 3.0 kW  

L/N/PE 

5.5 

Terminal Bl ock 

25.5 

14.9 gal/56 L 

E1242C E-2B230-PM000* 

230/400 

2  X 3.0 kW  

2L/N/PE 

5.5 

Terminal Bl ock 

12.5 

14.9 gal/56 L 

Содержание E1241IN-1B123-PM000

Страница 1: ...ractor Plus Brewing System FETCO PLUS Commercial Beverage Equipment CBS 1242 CBS 1241 1 gallon Extractor Plus Brewers shown with 1 gallon L4D dispenser sold separately CONTACT INFORMATION FETCO FOOD E...

Страница 2: ...elay Weights and Capacities Model Height Width Depth Water tank capacity Empty Weight Filled Weight Shipping Weight Shipping Dimensions CBS 1241 Brewer 34 in 880 mm 11 in 300 mm 20 3 8 in 520 mm 4 5 g...

Страница 3: ...i on Phase Amp Dr aw Brew Volum e per hour E1241C E 1B130 PM000 230 1 X 3 0 kW L N PE 2 8 EU1 16P 1 12 5 7 7 gal 29 1 L CBS 1241PLUS Single 1 Gallon 3 0 4 0 Liter Coffee Brewers Field configurable Int...

Страница 4: ...rew basket 5 Select a batch hold the corresponding BREW button in for 1 second to start 6 STOP button will illuminate Countdown time will display Selected BREW button will flash to indicate brew is in...

Страница 5: ...3 Service Phone G15 Rt Brews A90 Copy Batch B13 Filter Life F14 Override Lt BBS See Page 12 A91 Copy Batch From F15 Override Rt BBS A92 PASTE To F16 Override Lt BBL F17 Override Rt BBL Left and Right...

Страница 6: ...brew time is 5 30 minutes A2 30 Prewet Perc 0 0 00 25 0 1 Percentage of total brew volume A2 40 Prewet Delay Brew pause after prewet completes 0 1 00 Min 0 10 5 00 1 00 min The time between prewettin...

Страница 7: ...mperature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 205 212 0 96 100 0 500 152 205 211 0 96 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762 2...

Страница 8: ...Activates valve Default is 10 sec Toggle OFF or ON Runs valve to verify flow NOTE Have container under brew basket D4 Rt right Brew Valve Test Press to test Activates valve Default is 10 sec Toggle OF...

Страница 9: ...te 1 85 liter minute 64 ounces minute 0 42 0 58 Gallons 1 55 2 20 Liters 53 74 fl ounces 0 01G 0 05L 1 oz Adjusts flow rate E6 LT Bypass valve flow rate 0 37 gallon minute 1 60 liters minute 47 ounces...

Страница 10: ...NO Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F10 Restore Defaults NO NO YES Reset to factory When selecting F10 RESTORE...

Страница 11: ...k did not refill within expected time Water supply flow rate is too low Watch for short potting during brew cycle Investigate cause of low flow rate Clogged water filter 200 Heating flatline Tank is b...

Страница 12: ...nt Totalized cycles of valve operation CBS 1241 CBS 1242 G29 A Rt Brew Cycles R G30 A Rt Brew Volume LT Right brew valve flow through volume Gallons Liters Totalized volume through right valve CBS 124...

Страница 13: ...toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT Note Only the left side buttons of a two sided brewer are used for programming NOTE User Settings will be er...

Страница 14: ...such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petroleum based polish a...

Страница 15: ...ible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in a position to facilitate filter replacement 6...

Страница 16: ...nit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or aut...

Страница 17: ...BB HANDLE 1023 00191 00 GREEN PLUG BB HANDLE 1023 00192 00 ORANGE PLUG BB HANDLE 1023 00180 00 BLUE PLUG BB HANDLE Stainless Steel Brew Basket Ref Qty Part Number Description B003218B1 Complete Stain...

Страница 18: ...sions of all information Page 18 User Guide Operator instructions P212e0November 2021 Parts Diagram CBS 1241 FETCO CBS 1241 Drawing Number 1101 00580 00 6 Part Number1102 00471 00 ELECTRICAL COMPONENT...

Страница 19: ...1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 31 1 1046 00003 00 LABEL CSD WARNING 1 5 X 5 0 32 1 1041 00033 00 BLACK EXTRACTOR PLUS LABEL LASER ENGRAVED 33 1 1402 00097 10 WI...

Страница 20: ...ions of all information Page 20 User Guide Operator instructions P212e0November 2021 Parts Diagrams CBS 1242 FETCO CBS 1242 Drawing Number 1101 00579 00 6 Part Number1102 00471 00 ELECTRICAL COMPONENT...

Страница 21: ...2232 42 28 1 1001 00409 00 COVER UPPER BASE CBS 2232 42 29 12 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X LG 30 1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 31 2 1046 00...

Страница 22: ...ATED 9 1 1107 00030 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 1 1107 00031 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 1 1107 00029 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 9 1 1107 00037 00 HEATER...

Страница 23: ...0 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00030 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 2 1107 00031 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 2 1107 00029 00 HEATER ASSEMBLY...

Страница 24: ...8 12 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00037 00 HEATER ASSEMBLY IMMERSION 2300W 240VAC 9 2 1107 00005 00 HEATER ASSEMBLY IMMERSION 3000W 240VAC 9 2 1107 00010 00 HEATER ASSEM...

Страница 25: ...1102 00113 00 SWITCH REED ASSEMBLY 5 1 1102 00479 00 ASSEMBLY CASCADE SPRAY DOME NEXT GEN ORANGE 6 2 1057 00076 00 VALVE ASSEMBLY COMPLETE NG DELTROL interchangeable with 1057 00078 00 6 2 1057 00078...

Страница 26: ...6 User Guide Operator instructions P212e0November 2021 Wiring Diagrams SSR SSR SKU E1231 US 1X117 Domestic Dual Voltage Brewer is supplied by factory as 120VAC For 208 240 volt application conn ect L1...

Страница 27: ...ons of all information Page 27 User Guide Operator instructions P212e0November 2021 S S R Wiring diagram 1401 00190 10 CBS 1241PLUS SKU E1241US 1A115 PM001 E1241US 1A123 PM002 E1241IN 1B123 PM000 E124...

Страница 28: ...ions of all information Page 28 User Guide Operator instructions P212e0November 2021 SSR Wiring diagram 1401 00196 10 CBS 1242 PLUS SKU E1242US 1B223 PM000 E1242US 1B230 PM000 E1242IN 1B223 PM000 E124...

Отзывы: