background image

INPUTS

 

Programming 

Items 

Factory set  

Default 

Programming Range 

(display)

 

Notes

 

 

Display Inputs

 

 

Input Summery

    

R. Brew Basket Sens. [ single/dual] 
L. Brew Basket Sens. 
H. Liquid Level probe 
H. Tank Temperature Probe 
L. Tank Temperature Probe 
SD Card Recognized 
Tank Temp.     200

 

†

 

„

 

„

 

„

 

„

 

†

 

 

 

Cal. Touch Scr 

 
 

Calibrate 

Calibrate

 

________________

[]

____ 

YES                NO

 

If Yes:  

Follow directions on the 

touch screen

 

 

GENERAL

 

Programming 

Items 

Factory set  

Default 

Programming Range 

(display)

 

Notes

 

Tank Temp.

 

 200°F 

200  °F 

|______________

[]

___| 

170                          207

 

Correction for high 

altitude below 

Brew at Temp. 

OFF

 allows 

brewing at any 
temperature. 

 

“ON” 

ON 

|________

[]

_______| 

OFF       ON   AUTO

 

SEE NOTE BELOW!  

Units of Meas. 

 

  Temperature  

°C 

or

 °F 

°F 

|___

[]

____________| 

°F              °C 

[Switchable Units] 

 

  Volume  

Gallons [Liters] 

Gallons 

|___

[]

____________| 

Gallons       Liters

 

[Switchable Units] 

ECO Mode 

Energy Saving 

Mode 

OFF 

ECO Mode

 

_______________

[]

_____ 

ON               OFF

 

If Selected: Lowers hot 

water tank temperature to 

170

°

F after 1 hour of 

inactivity

 

Logo Timeout

 

 0:30 

mm:ss 

0:30 mm:ss 

|__

[]

___________| 

0:15                    5:00

 

 

Brew B. Sensor

 

 NORMAL 

NORMAL 

|__

[]

____________| 

NORMAL     OVERRIDE

 

Factory or service use for 

servicing. 

NORMAL

 is 

recommended for safety.  

 

Use Flowjet 

 NO 

NO

 

____

[]

_______________ 

NO                YES 

Trims water handling 

system for Flowjet 

LLC Sensitivity 

Normal for most water 
“HIGH” for R.O. 

NORMAL 

NORMAL

 

____

[]

______________ 

NORMAL                HIGH 

Sets sensitivity for liquid 

level control.  

High is for reverse osmosis 

water or other very pure 

water.

 

Chart to correct for altitude for boiling point   

in tank water temperature.

 

[ft] [m] 

Suggested 
Setting[°F] 

Boiling 

point[°F] 

Suggested 

Setting[°C] 

Boiling 

point [°C] 

0 0 200 

212.0 

93 

100.0 

500 152  200

 

211.0 93

 

99.5 

1000 305  200

 

210.1 93

 

98.9 

2000 610  200

 

208.1 93

 

97.8 

2500 762  200

 

207.2 93

 

97.3 

3000 914  200

 

206.2 93

 

96.8 

3500 1067  197  205.3  92  96.3 
4000 1219  195  204.3  91  95.7 
4500 1372  194  203.4  90  95.2 
5000 1524  194  202.4  90  94.7 
5500 1676  193  201.5  89  94.2 
6000 1829  192  200.6  89  93.6 
6500 1981  191  199.6  88  93.1 
7000 2134  190  198.7  87  92.6 
7500 2286  188  197.8  86  92.1 
8000 2438  187  196.9  86  91.6 
8500 2591  185  196.0  85  91.1 

BREW AT TEMPERATURE DEFINITONS 

BREW AT TEMP

:  

“ON”

 

(DEFAULT: FACTORY PROGRAMMED INTO BREWER) 

“BREW START” Batch Section Buttons will not be accessible until 
tank temperature is at set point.   
The “BREW START” screens with the Batch Section Buttons 
become accessible when hot water tank is at the selected 
temperature.  The screen at right displays when the “BREW AT 
TEMP” is selected. 

 

 

BREW AT TEMP:

  

AUTO              USER SELECTABLE  

This allows the “BREW START” to activate if the hot water tank is 
at the selected temperature—then brew will start.   
If the temperature is too low, the brewer will wait until the proper 
temperature is reached. A screen (example to the right) will 
display showing a thermometer icon and the tank temperature.   
IMPORTANT: ALWAYS have dispenser(s) under the brew 
baskets when in the BREW AT TEMP mode.

 

 

BREW AT TEMP:

  

OFF

             

USER SELECTABLE       (Not recommended) 

Allows brewing at any temperature above 179°F/82°C.    

May NOT apply for two sided brewer if one side is in brew cycle 

 
 
 

 
 
 

 

CBS_2132  3L 

 

„

  Ready                Tank Temp 

°F 

     

†

  Heating                

197

 

 

†

  Filling            

XTS

XTS

™ 

EXTRACTOR 

TOUCHSCREEN 

 

Regular 1 

     1.50 

Ÿ

 05:30 

 

Regular 2 

     1.50 

Ÿ

 05:30 

 

Decaf 1 

     1.50 

Ÿ

 05:30 

 

Decaf 2 

     1.00 

Ÿ

 05:30 

92°

C

 

INFO 

 

STOP 

Содержание CBS-2141XTS

Страница 1: ...tures Batch Parameters 7 How to calibrate the flow rate 10 Operator Training 12 Service Guide to a Successful Installation 13 Installation Directions 14 CBS 2140XTS Dimensions Utility Connections 18 E...

Страница 2: ...hanging volume brewed Factory settings The following are the factory set defaults all variables in the brew menu are adjustable Brew Volume and coffee filter size CBS 2140 single and Twin 1 gallon 3 8...

Страница 3: ...screen will briefly illuminate Turn main power switch to ON Switch located lower right side of back panel When Complete the HOME SCREEN will display Immediately touch and hold finger to enter programm...

Страница 4: ...wer rails Brewbasket s must be in place Have empty dispenser under brewbasket Use the convenient locator guide Tap READY screen to enter the batch selection menu A long duration TAP with fingertip Tou...

Страница 5: ...2142XTS brewing simaltanously Left side completing drip delay Brew basket sensor enabled Unit is brewable only when brebasket is in place option may be disabled by user CBS 2142XTS dual side right si...

Страница 6: ...gramming items shown below Programming category screens Menu Tree Programming category screens To enter Turn unit OFF After 10 second delay turn unit ON Home Screen will appear Immediately place finge...

Страница 7: ...ON _________ ________ ON OFF Batch Summary Display Summary Batch Name Regular 1 Regular 1 16 Write own name Batch Volume 1 50 gal 0 50 2 00 1 00 gal _________ ________ 0 50 2 00 Brew Time 4 00 mm ss...

Страница 8: ...perature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 200 212 0 93 100 0 500 152 200 211 0 93 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762 20...

Страница 9: ...ress to test TEST Press To Test Runs Valve to verify flow Have container under brewbasket R Valve Calib Calibrate Flow Rate 1540 ml p m _________ ________ 1400 1900 Factory or service use for flow rat...

Страница 10: ...the number 2 AUTOMATIC Built in CALIBRATE THE FLOW RATE Enter this number in milliliters into the calibration slider for the Valve tested in the OUTPUT MENU Use milliliters If measured in fluid ounce...

Страница 11: ...tivated Right Brew gal Right Bypass activated Right Bypass gal Fill valve Activated Fill Valve gal Heater Activated Heater ON time Touch To Return 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 Identical screen for...

Страница 12: ...cloth and hot suds on the outside to avoid scratches Never use abrasives that will scratch surface Weekly 1 Use a commercial coffee dispenser cleaner such as URNEX TABZ DIP IT or Squeak n Clean 2 Car...

Страница 13: ...nd waste piping and connections shall comply with the International Plumbing Code 2003 International Code Council ICC or to the Uniform Plumbing Code 2003 IAPMO 3 Use an inline water filter for all be...

Страница 14: ...the unit and verify that it will fit properly in the space intended for it Verify that the counter or table will support the total weight of the brewer and dispensers when filled See Technical Data 1...

Страница 15: ...le on the lower back 5 A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the brewer and its location and markings known to the operators 6 The t...

Страница 16: ...16...

Страница 17: ...E EXPORT Japan CBS_2142XTS Twin 1 gallon version Electrical Configurations Configuration Codes Plastic Brewbasket Stainless Steel Brewbasket Heater Configuration Voltage Phase Wires Electrical Connect...

Страница 18: ...b 18 6 kg 16 x 23 x 29 406 x584x737mm CBS 2142XTS Dual 1 gallon 34 873mm 19 502mm 20 518mm 47lb 21 3kg 92lb 41 7kg 114 4lb 51 9 kg 5 8 gal 22 1 l 58lb 26 3kg 23 x 25 x 29 584x635x737mm Rough in CBS 21...

Страница 19: ...ve Check inside of machine for leaks 107 Fault Lower liquid level probe Tank not filling Occurs during prefill low probe is uncovered 201 Heater open high limit thermostat or Solid State Relay SSR fau...

Страница 20: ...will be displayed P 8 After the water has reached the set temperature Screen 3 will display READY 9 Review the Operating Instructions Brew one full batch water only on each side to confirm proper fill...

Страница 21: ...1052 00001 00 POWER SUPPLY 90 264VAC 24VDC 1 8A 1 5 1029 00012 00 SPACER 25 HEX X 1 LG FEM 4 40 THREAD 4 CBS 2142 XTS Back Panel CE Drawings 1109 00047 00 SERVICE PARTS ITEM NO PART NO DESCRIPTION QTY...

Страница 22: ...00 ASSEMBLY BYPASS VALVE LEFT 1 9 1001 00181 00 COVER FRONT CBS 2100 XTS 2 10 1402 00051 00 HARNESS LOW AMP CBS 2142 52 XTS CE UL 1 11 1402 00060 00 HARNESS HIGH AMP CBS 2142 XTS UL 1 12 1057 00043 0...

Страница 23: ...003 00140 00 ALUMINUM BRACKET FOR SSR 2 6 1052 00033 00 RELAY SOLID STATE 50A 480VAC W BUILD IN VARISTOR 2 7 1081 00042 00 STANDOFF 1 4 HEX 4 8 1112 00019 00 PROBE WELDMENT WATER LEVEL 2 600 LG 1 9 11...

Страница 24: ...1 10 1073 00002 00 LEG FLANGE FOOT 4 0 HIGH 4 11 1057 00043 00 SOLENOID VALVE SINGLE 180 DEG 24VDC 1 12 1102 00243 00 ADAPTER ASSY 3 4 BSP x 1 4 NPT x 3 8 TUBE 1 13 1023 00147 00 PLUG TANK SERVICE DRA...

Страница 25: ...SHOT THERMOSTAT 2 4 1053 00003 00 THERMOSTAT SINGLE SHOT 240V 40A 2 5 1003 00140 00 ALUMINUM BRACKET FOR SSR 2 6 1052 00033 00 RELAY SOLID STATE 50A 480VAC W BUILD IN VARISTOR 2 7 1081 00042 00 STANDO...

Страница 26: ...250VAC 1 4 1052 00001 00 POWER SUPPLY 90 264VAC 24VDC 1 8A 1 5 1029 00012 00 SPACER 25 HEX X 1 LG FEM 4 40 THREAD 4 CBS 2141 XTS Back Panel CE Drawings 1109 00046 00 SERVICE PARTS ITEM NO PART NO DES...

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Отзывы: