Insert Brewbasket! 

 
 
 
 
 
 
 

OTHER

 

Programming 

Items 

Factory set  

Default 

Programming Range 

(display)

 

Notes

 

Error Codes  

 Display Errors  

(Codes) 

1: 
2: 
3:

 

See Error Code Chart 

for references 

 

 Reset Errors  

(Reset) 

Reset

 

|_______________

[]

____| 

YES                NO

 

!!Errors must be 

corrected and cleared!!

Copy Program  

 From SD to B. 

SD

Æ

 Brewer 

SD

Æ

 Brewer

 

|________________

[]

____ 

YES                NO

 

Setup upload

 

---------------------------------------------------------------------------

Please insert SD card with 

the setup data!

 

 

 From B to SD 

Brewer

Æ

 SD 

Brewer

Æ

 SD

 

|________________

[]

____| 

YES                NO

 

Setup download

 

---------------------------------------------------------------------------

Please insert SD card with  

sufficient space 

(

2GB)

 

Upload Logo  

 

Upload Logo  

UPLOAD LOGO 

Are you sure 

|________________

[]

____| 

YES                NO

 

Please insert SD card 

with logo file! 

Res to Factory 
& Select 
Brewer Type  

See next line: 

Select Brewer 

Configuration

  

Reset to default 

Reset to Default 

Are you sure 

|________________

[]

____| 

YES                NO

 

Completely overwrites 

all user setup, incl. 

user logo. 

Select Brewer 
Configuration 

CBS_2131 3L; CBS_2131 1G 

CBS_2132 3L; CBS_2132 1G 

CBS_2141; CBS_2142 

CBS_2151; CBS_2152 

Screen appears 
after pressing “Res 
to Factory”

 

..

[Above]

 

Select Model 

CBS [2131-2152]Series 

|________________

[]

____| 

Scroll to your 

brewer and tap 

ENTER tab 

Total Counters 

Counters 

 Display Counters 

    -OR- 

 Display 

Resettable 
Counters 

Counters 

Display Total 

Counters 

Left Brews 
Left Brew activated 
Left Brew [gal] 
Left Bypass activated 
Left Bypass [gal] 
Right Brews 
Right Brew activated 
Right Brew [gal] 
Right Bypass activated 
Right Bypass [gal] 
Fill valve Activated 
Fill Valve [gal] 
Heater Activated 
Heater “ON” time 

Touch To Return 














0:00 

 

Identical screen for  

Resettable Counters 

Will display when 
selected.  See next 
line to reset to zero 
 

NOTE: 

Total Counters

” is 

not user resettable 

Reset Counters 

 

 Resets 

Counters  

Reset All 

Counters 

Reset All Counters 

Are you sure 

|________________

[]

____| 

YES                NO

 

Resetting will restart 

counter from zero 

Firmware  

 

Firmware 

Version 
-Software type

 

Display Firmware 
Version 

CBS_2142 [or model type] 

SW ver 2.1.0Z 

HW ver 1.1.3 

QP ver. 4.5.01

 

Displays firmware 

version 

 

 Update 

Firmware  

UPDATE  

UPDATE

 

|________________

[]

____| 

YES                NO

 

Firmware upload

 

---------------------------------------------------------------------------

Please insert SD card with 

the firmware file!

 

DEMO Mode 

DEMO ON/OFF 

 

OFF

 

|________________

[]

____| 

ON                OFF

 

Demonstrates the controls for 

training. Disables all 

components in demo mode. 

Error code 001: Software error-error on start up or corrupted software  
Error code 50: Shorted temperature probe 

ERROR CODES

 

Error code 51: Open temperature probe 

 

Error code 100: Initial Fill Error.  Initial fill time was more than 4 minutes after power up. 

 

Error code 101: Error on refill 

 

Error code 102: Unwanted fill; possible leak 

 

Error code 103: Liquid level probe fault 

 

Error code 201: Heater open, high limit thermostat, or Solid State Relay (SSR) fault 

 

Error code 255: Touch pad error, usually from longer than 2 min touch contact 

 

ENTER

 

Regular 1 

     1.50 

Ÿ

 05:30 

 

Regular 2 

     1.50 

Ÿ

 05:30 

 

Decaf 1 

     1.50 

Ÿ

 05:30 

 

Regular 1 

     1.50 

Ÿ

 05:30 

 

!

INSERT 

BREW 

BASKET 

Содержание CBS-2141XTS

Страница 1: ...tures Batch Parameters 7 How to calibrate the flow rate 10 Operator Training 12 Service Guide to a Successful Installation 13 Installation Directions 14 CBS 2140XTS Dimensions Utility Connections 18 E...

Страница 2: ...hanging volume brewed Factory settings The following are the factory set defaults all variables in the brew menu are adjustable Brew Volume and coffee filter size CBS 2140 single and Twin 1 gallon 3 8...

Страница 3: ...screen will briefly illuminate Turn main power switch to ON Switch located lower right side of back panel When Complete the HOME SCREEN will display Immediately touch and hold finger to enter programm...

Страница 4: ...wer rails Brewbasket s must be in place Have empty dispenser under brewbasket Use the convenient locator guide Tap READY screen to enter the batch selection menu A long duration TAP with fingertip Tou...

Страница 5: ...2142XTS brewing simaltanously Left side completing drip delay Brew basket sensor enabled Unit is brewable only when brebasket is in place option may be disabled by user CBS 2142XTS dual side right si...

Страница 6: ...gramming items shown below Programming category screens Menu Tree Programming category screens To enter Turn unit OFF After 10 second delay turn unit ON Home Screen will appear Immediately place finge...

Страница 7: ...ON _________ ________ ON OFF Batch Summary Display Summary Batch Name Regular 1 Regular 1 16 Write own name Batch Volume 1 50 gal 0 50 2 00 1 00 gal _________ ________ 0 50 2 00 Brew Time 4 00 mm ss...

Страница 8: ...perature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 200 212 0 93 100 0 500 152 200 211 0 93 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762 20...

Страница 9: ...ress to test TEST Press To Test Runs Valve to verify flow Have container under brewbasket R Valve Calib Calibrate Flow Rate 1540 ml p m _________ ________ 1400 1900 Factory or service use for flow rat...

Страница 10: ...the number 2 AUTOMATIC Built in CALIBRATE THE FLOW RATE Enter this number in milliliters into the calibration slider for the Valve tested in the OUTPUT MENU Use milliliters If measured in fluid ounce...

Страница 11: ...tivated Right Brew gal Right Bypass activated Right Bypass gal Fill valve Activated Fill Valve gal Heater Activated Heater ON time Touch To Return 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 Identical screen for...

Страница 12: ...cloth and hot suds on the outside to avoid scratches Never use abrasives that will scratch surface Weekly 1 Use a commercial coffee dispenser cleaner such as URNEX TABZ DIP IT or Squeak n Clean 2 Car...

Страница 13: ...nd waste piping and connections shall comply with the International Plumbing Code 2003 International Code Council ICC or to the Uniform Plumbing Code 2003 IAPMO 3 Use an inline water filter for all be...

Страница 14: ...the unit and verify that it will fit properly in the space intended for it Verify that the counter or table will support the total weight of the brewer and dispensers when filled See Technical Data 1...

Страница 15: ...le on the lower back 5 A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the brewer and its location and markings known to the operators 6 The t...

Страница 16: ...16...

Страница 17: ...E EXPORT Japan CBS_2142XTS Twin 1 gallon version Electrical Configurations Configuration Codes Plastic Brewbasket Stainless Steel Brewbasket Heater Configuration Voltage Phase Wires Electrical Connect...

Страница 18: ...b 18 6 kg 16 x 23 x 29 406 x584x737mm CBS 2142XTS Dual 1 gallon 34 873mm 19 502mm 20 518mm 47lb 21 3kg 92lb 41 7kg 114 4lb 51 9 kg 5 8 gal 22 1 l 58lb 26 3kg 23 x 25 x 29 584x635x737mm Rough in CBS 21...

Страница 19: ...ve Check inside of machine for leaks 107 Fault Lower liquid level probe Tank not filling Occurs during prefill low probe is uncovered 201 Heater open high limit thermostat or Solid State Relay SSR fau...

Страница 20: ...will be displayed P 8 After the water has reached the set temperature Screen 3 will display READY 9 Review the Operating Instructions Brew one full batch water only on each side to confirm proper fill...

Страница 21: ...1052 00001 00 POWER SUPPLY 90 264VAC 24VDC 1 8A 1 5 1029 00012 00 SPACER 25 HEX X 1 LG FEM 4 40 THREAD 4 CBS 2142 XTS Back Panel CE Drawings 1109 00047 00 SERVICE PARTS ITEM NO PART NO DESCRIPTION QTY...

Страница 22: ...00 ASSEMBLY BYPASS VALVE LEFT 1 9 1001 00181 00 COVER FRONT CBS 2100 XTS 2 10 1402 00051 00 HARNESS LOW AMP CBS 2142 52 XTS CE UL 1 11 1402 00060 00 HARNESS HIGH AMP CBS 2142 XTS UL 1 12 1057 00043 0...

Страница 23: ...003 00140 00 ALUMINUM BRACKET FOR SSR 2 6 1052 00033 00 RELAY SOLID STATE 50A 480VAC W BUILD IN VARISTOR 2 7 1081 00042 00 STANDOFF 1 4 HEX 4 8 1112 00019 00 PROBE WELDMENT WATER LEVEL 2 600 LG 1 9 11...

Страница 24: ...1 10 1073 00002 00 LEG FLANGE FOOT 4 0 HIGH 4 11 1057 00043 00 SOLENOID VALVE SINGLE 180 DEG 24VDC 1 12 1102 00243 00 ADAPTER ASSY 3 4 BSP x 1 4 NPT x 3 8 TUBE 1 13 1023 00147 00 PLUG TANK SERVICE DRA...

Страница 25: ...SHOT THERMOSTAT 2 4 1053 00003 00 THERMOSTAT SINGLE SHOT 240V 40A 2 5 1003 00140 00 ALUMINUM BRACKET FOR SSR 2 6 1052 00033 00 RELAY SOLID STATE 50A 480VAC W BUILD IN VARISTOR 2 7 1081 00042 00 STANDO...

Страница 26: ...250VAC 1 4 1052 00001 00 POWER SUPPLY 90 264VAC 24VDC 1 8A 1 5 1029 00012 00 SPACER 25 HEX X 1 LG FEM 4 40 THREAD 4 CBS 2141 XTS Back Panel CE Drawings 1109 00046 00 SERVICE PARTS ITEM NO PART NO DES...

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Отзывы: