Starting The Brew  

 

1. Turn the power switch “ON”.   
2. Prepare a brew basket with the correct size

 

filter and appropriate amount of coffee. 

3. Slide the brew basket completely into the

 

rails. 

4. Place a clean, empty, preheated dispenser

 

under the brew basket. 

5. Select a batch & hold the corresponding BREW button in

 

for 1 second to start  

6. -STOP button will illuminate,  Brew Selector button will illuminate 
    -Countdown time will display.  Default time setting is 6:00 (six minutes)  
   -Selected BREW button will slowly pulsate to indicate brew is in progress.  
    -All other BREW buttons for that brew head will be unlit. 
 
7. When the brew cycle is finished, 
STOP

 

button will extinguish and the BREW button will

 

continue to pulsate to indicate 

DRIP will display to show the 2:00 (two minutes) drip delay setting. 
This

 

indicates that coffee may still be dripping from

 

the brew basket 

For safety- do not remove brew basket until drip-out is complete.

 

 

Enter Programming 

There are 7 menu groups-A-F plus EXIT (G).   

See the following pages for the batch parameter definitions and all settings for the brewer

 

 
 

 
 

 
 

 

TO ENTER PROGAMMING 

1-Turn brewer “OFF” from power switch 
2-Turn power switch to “ON” 

 
…Screen will initialize  and then 
 display digital process notifications 

 
3-After Initialization- “STOP” Lamp turns on 
4-Quickly press  “STOP” button (no need to hold) 

 

 

 

 
 

 

 

 
 

 

 

 
      

 When brewer is In PROGRAMMING MODE 

      -the screen will display:

 

       

                         

|BATCH PRG| 
|A   

(or B-F)

   | 

-

Illuminated LED indicates active keypad positions 

 

See the following pages for batch parameter 

definitions and all settings for the brewer

 

Exit Programming & Save Control Setting Changes 

 

 

From any screen-

Press STOP button 

until the EXIT (“G”)  

screen appears 

From the “G” screen 

Press button 

2

 to 

toggle to the EXIT-

YES

 screen 

From EXIT screen 

Press  button 

1

 to 

toggle to the SAVE 

screen 

From SAVE screen 

Press button 

2

 to 

toggle to the SAVE-

YES

 screen 

To SAVE and EXIT 

Press button 

1

 to 

SAVE your changes 

and EXIT to  

OPERATING MODE  

 

STOP 

 

 

 

Programming A-F 

A-F 

 

 

 

 

STOP 

 

EXIT 

NO    + 

 

 

 

 

 

 

STOP 

 

EXIT 

YES    - 

 

 

 

 

 

STOP 

 

 

 

SAVE 

NO  + 

 

 

 

 

STOP 

 

 

 

SAVE 

YES  - 

 

 

 

STOP

 

FETCO 

Ready to Brew 

STOP

 

 

Brewing 

5:30

 

STOP BUTTON

 

 

ON/OFF switch 
is located on 
lower right on 
back of brewer 

STOP 

CBS-1221 

Ver.3.0.2019 

 

STOP 

   Batch Program 
   A

 

 

 

Содержание CBS-1221

Страница 1: ...2 2 5 liter 3 liter and 3 8 liter air pots 1 9L server Value priced Self cleaning spray head patented for mineralization resistance E1221US 1X117 KM001 FETCO CBS 1221 brewer Gourmet plastic brew bask...

Страница 2: ...4 minute brew time 2 0 minute drip delay all recipes Brew Process parameters are user controllable for Brew Volume Brew Time Prewet Percent and Prewet Delay Drip Delay Weights and Capacities Dispenser...

Страница 3: ...er Programming There are 7 menu groups A F plus EXIT G See the following pages for the batch parameter definitions and all settings for the brewer TO ENTER PROGAMMING 1 Turn brewer OFF from power swit...

Страница 4: ...72 PASTE To F10 Error Log F11 Erase Error Log F12 Service Phone The A menus A1 3 correspond to batch buttons 1 3 on the touch panel Access the A menus to PROGRAM make changes to individual menu recipe...

Страница 5: ...or off Batches may be individually enabled rewritten or deactivated A21 Batch Volume 2 20liters 0 58gal 0 95 to 3 25L 0 25 to 0 85 gal 0 05L 0 01G Unit software is in liters converts to gallon A22 Br...

Страница 6: ...2 5000 1524 194 202 4 90 94 7 5500 1676 193 201 5 89 94 2 6000 1829 192 200 6 89 93 6 6500 1981 191 199 6 88 93 1 7000 2134 190 198 7 87 92 6 7500 2286 188 197 8 86 92 1 8000 2438 187 196 9 86 91 6 85...

Страница 7: ...r under brew basket Single series displays right side only Left Valve display is only for twin side brewer D9 LCD Brightness Brightness 90 20 100 5 Adjust LCD screen brightness only Not for LEDs under...

Страница 8: ...l The software sets equipment to brewer defaults SETTING F3 4 When loading from USB Reprograms settings SETTING E7 5 When restoring defaults Reloads to defaults SETTING E8 F SERVICE MENU Software Code...

Страница 9: ...r the brewer to reach operating temperature ERROR CODES DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND OR CORRECTED Contact specialized personnel for error codes Code Description Possible Caus...

Страница 10: ...5 Dry the face of the touch pad before turning on power 6 Do not electrically energize this equipment or attempt operation without all covers in place and all screws fastened 7 Unplug machine before...

Страница 11: ...Install the filter unit after a water shutoff valve and in a position to facilitate filter replacement 5 The water line and newly installed filter cartage must be flushed thoroughly prior to connectin...

Страница 12: ...with the specified cord only from the manufacturer in order to avoid a hazard 8 Review the dimensions for the unit and verify that it will fit properly in the space intended for it Verify that the co...

Страница 13: ...ET SHORT SILICONE LEVEL AND TEMP PROBE 9 1 1112 00002 00 PROBE WELDMENT WATER LEVEL 2 25 LONG 10 1 1102 00161 00 PROBE ASSEMBLY TEMP AND LLC 8 LONG 11 1 1023 00362 00 FITTING VENT ELBOW 375 X 375 SELF...

Страница 14: ...Go to fetco com for the latest versions of all information Page 14 User Guide Operator instructions P194Re0 November 2020...

Страница 15: ...RETROFIT 16 2 1 1102 00479 00 ASSEMBLY CASCADE SPRAY DOME NEXT GEN BLUE 16 3 1 1023 00342 00 QUICK CONNECT CLIP 16 4 1 1057 00076 00 VALVE ASSEMBLY COMPLETE NG DELTROL 17 1 1024 00063 00 O RING 3 15...

Страница 16: ...00 SCREW 1 4 20 X 5 FL HD PH W NYLN 4 1 1009 00006 00 WIRE BASKET 5 1 1102 00064 00 HANDLE W MAGNET ASY BLACK Optional colored handle 1102 00065 00 HANDLE W MAGNET ASY RED Optional colored handle 1102...

Страница 17: ...Go to fetco com for the latest versions of all information Page 17 User Guide Operator instructions P194Re0 November 2020 Wiring Diagram...

Страница 18: ...End of section notes N...

Отзывы: