background image

Go to fetco.com for the latest versions of all information         

Page 10

      

User Guide & Operator instructions

   

P194

Re0

 November  2020

 

Cleaning & Maintenance  

 

 

 

 

 

 

 

 

After Each Brew: 

1.  Dispose of grounds and rinse brew basket. 
2.  Never strike a brew basket or hit it against a hard surface.   
      This will damage the brew cone, and may damage the brew basket support rails 
3.  Rinse dispensers before reuse.

 

Every Day: 

1.  Wash brew basket with hot sudsy water.  
2.  Pull CSD from the spray head, it is magnetically attached.  Use gloves or a heavy towel. 

      

Wash off any film and reattach.  Use vinegar if limescale filming is present. 

3.  Clean dispensers with hot suds water and a brush, rinse and air dry. 
4.  Use only a soft cloth and hot suds on the outside to avoid scratches.  Never use abrasives that will scratch surface. 

Weekly  

1.  Use a commercial coffee dispenser cleaner such as URNEX™, TABZ™, DIP-IT™ or Squeak 'n Clean™.   
2.  Carefully Follow the instructions supplied with the cleaning product 
3.  Never use spray cleaners, solvent, solvent based cleaner or petroleum based polish anywhere on dispensers 

Warning 

1.  Turn off power before any cleaning procedure, including wiping the exterior for appearance reasons.  
2.  Dry the exterior, especially the face panel, before turning on power. 
3.  Do not apply any type of spray cleaner on the face panel of this equipment. 
4.  Never use solvent or solvent-based cleaner or petroleum based polish anywhere on this equipment.  
5.  Dry the face of the touch pad before turning on power 
6.  Do not electrically energize this equipment or attempt operation without all covers in place and all screws fastened. 
7.  Unplug machine before disassembly or servicing. 

Safety Notes 

1.  Professional installation is required.  This appliance is manufactured only for commercial use 
2.  Operational requirements and maintenance for commercial cooking appliances differ from household appliances.   
3.  Operators must be trained for this equipment and must understand the use, maintenance and hazards.  
4.  Access to the service area is restricted to persons having safety/hygiene knowledge and practical experience of the 

coffee brewer.  This appliance must be installed in locations where it can be overseen by adult trained personnel. 

5.  Do not attempt to move hot beverage equipment once it is filled.  Drain equipment before moving. 
6.  FETCO commercial coffee brewers prepare large amounts of coffee or tea in a single batch using very hot water 
7.  Commercial coffee brewers provide very hot water from the spray head, brew basket and faucet when it is pulled.  
8.  Coffee brewers may continue to dispense very hot water from the mechanically operated faucet after the electronic 

touchpad is completely disabled by turning off the power switch on the lower back of the unit, or unplugging the unit.  

9.  For safety, the brewer control locks the brew basket for 6.0 minutes after starting the brew.  
10.  Never attempt to defeat the factory set (default) time that the brew basket is locked for safety from start of brew.   

 

Keep these instructions for training and future reference. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание CBS-1221

Страница 1: ...2 2 5 liter 3 liter and 3 8 liter air pots 1 9L server Value priced Self cleaning spray head patented for mineralization resistance E1221US 1X117 KM001 FETCO CBS 1221 brewer Gourmet plastic brew bask...

Страница 2: ...4 minute brew time 2 0 minute drip delay all recipes Brew Process parameters are user controllable for Brew Volume Brew Time Prewet Percent and Prewet Delay Drip Delay Weights and Capacities Dispenser...

Страница 3: ...er Programming There are 7 menu groups A F plus EXIT G See the following pages for the batch parameter definitions and all settings for the brewer TO ENTER PROGAMMING 1 Turn brewer OFF from power swit...

Страница 4: ...72 PASTE To F10 Error Log F11 Erase Error Log F12 Service Phone The A menus A1 3 correspond to batch buttons 1 3 on the touch panel Access the A menus to PROGRAM make changes to individual menu recipe...

Страница 5: ...or off Batches may be individually enabled rewritten or deactivated A21 Batch Volume 2 20liters 0 58gal 0 95 to 3 25L 0 25 to 0 85 gal 0 05L 0 01G Unit software is in liters converts to gallon A22 Br...

Страница 6: ...2 5000 1524 194 202 4 90 94 7 5500 1676 193 201 5 89 94 2 6000 1829 192 200 6 89 93 6 6500 1981 191 199 6 88 93 1 7000 2134 190 198 7 87 92 6 7500 2286 188 197 8 86 92 1 8000 2438 187 196 9 86 91 6 85...

Страница 7: ...r under brew basket Single series displays right side only Left Valve display is only for twin side brewer D9 LCD Brightness Brightness 90 20 100 5 Adjust LCD screen brightness only Not for LEDs under...

Страница 8: ...l The software sets equipment to brewer defaults SETTING F3 4 When loading from USB Reprograms settings SETTING E7 5 When restoring defaults Reloads to defaults SETTING E8 F SERVICE MENU Software Code...

Страница 9: ...r the brewer to reach operating temperature ERROR CODES DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND OR CORRECTED Contact specialized personnel for error codes Code Description Possible Caus...

Страница 10: ...5 Dry the face of the touch pad before turning on power 6 Do not electrically energize this equipment or attempt operation without all covers in place and all screws fastened 7 Unplug machine before...

Страница 11: ...Install the filter unit after a water shutoff valve and in a position to facilitate filter replacement 5 The water line and newly installed filter cartage must be flushed thoroughly prior to connectin...

Страница 12: ...with the specified cord only from the manufacturer in order to avoid a hazard 8 Review the dimensions for the unit and verify that it will fit properly in the space intended for it Verify that the co...

Страница 13: ...ET SHORT SILICONE LEVEL AND TEMP PROBE 9 1 1112 00002 00 PROBE WELDMENT WATER LEVEL 2 25 LONG 10 1 1102 00161 00 PROBE ASSEMBLY TEMP AND LLC 8 LONG 11 1 1023 00362 00 FITTING VENT ELBOW 375 X 375 SELF...

Страница 14: ...Go to fetco com for the latest versions of all information Page 14 User Guide Operator instructions P194Re0 November 2020...

Страница 15: ...RETROFIT 16 2 1 1102 00479 00 ASSEMBLY CASCADE SPRAY DOME NEXT GEN BLUE 16 3 1 1023 00342 00 QUICK CONNECT CLIP 16 4 1 1057 00076 00 VALVE ASSEMBLY COMPLETE NG DELTROL 17 1 1024 00063 00 O RING 3 15...

Страница 16: ...00 SCREW 1 4 20 X 5 FL HD PH W NYLN 4 1 1009 00006 00 WIRE BASKET 5 1 1102 00064 00 HANDLE W MAGNET ASY BLACK Optional colored handle 1102 00065 00 HANDLE W MAGNET ASY RED Optional colored handle 1102...

Страница 17: ...Go to fetco com for the latest versions of all information Page 17 User Guide Operator instructions P194Re0 November 2020 Wiring Diagram...

Страница 18: ...End of section notes N...

Отзывы: