Possible causes
Solution
Filter bag full.
Insert a new filter bag
(see section
).
Dirty main filter.
Clean the main filter
(see section
).
Change the main filter
(see section
).
Suction hose is
blocked or kinked.
Eliminate the block or
straighten the hose.
Value set on the
suction power ad
justment [1-14] is
too low.
Set the suction power
to a higher value (see
Battery charge level
low.
– Charge the battery
packs.
– Use new battery
packs.
Electronic monitor
ing malfunction.
Have the fault rectified
by a Festool service
workshop.
Working with sand
ers.
Activate the bypass
function (see sec
tion
).
10.4 Temperature cut-out
To protect against overheating, the tempera
ture cut-out switches off the cordless mobile
dust extractor before it reaches the critical
temperature. The status display LED [1-15] in
dicates a fault.
LED lights up red
Excessive temperature
► Switch off the cordless mobile dust extrac
tor, let it cool down.
► Switch the cordless mobile dust extractor
on again after approx. ten minutes.
10.5 SysDoc
WARNING
Risk of injury
► Do not stand on the storage area of the
cordless mobile dust extractor.
CAUTION
Risk of injury
► When transporting, ensure that the T-Loc
is closed.
A Systainer can be fastened to the storage area
of the hose holder [1-3] with the T-Loc
lock [1-4].
10.6 Applying the brake
► Raise the front of the cordless mobile dust
extractor slightly.
► Push down the brake [1-10] until it engages
into position.
► Actuate the release button [1-11] to release
it.
11 Working
11.1 Extracting dry materials
CAUTION
Hazardous dust
Damage to the respiratory passage
► Always use a filter bag!
► Check that the main filter is undamaged
before extracting.
When extracting dust that exceeds the
limit value, only extract from one dust
source (power or compressed-air tool).
Observe the following when extracting dust
generated by operating power tools:
Ensure there is adequate ventilation! Observe
regional regulations!
Limit values: Exhaust air max. 50% of the fresh
air volume
Equation: Room volume V
R
x air renewal rate
L
W
11.2 Extracting wet materials/liquids
Remove the filter bag!
Use a special wet filter.
The dust extraction stops automatically when
the maximum fill level is reached.
The bottom LED [1-15] lights up red.
► Switch off the mobile dust extractor [1-12].
► Open the locking clips [1-7] and remove the
top section of the machine.
► Empty the dirt trap [1-9].
After wet extraction, allow the main filter to dry!
Dry the mobile dust extractor before extracting
dry dust.
English
24
Содержание 577065
Страница 3: ...3 1 1 2 2x 2x click 2 3 4a 4b 2 1 ...
Страница 5: ...8 9 3 2 1 45 45 ...
Страница 6: ......