Rules for set-up
Rules for set-up
Number of modules
Minimum: adapter plate VABA + 1 end plate VABE
Maximum: adapter plate VABA + 3 m end plate VABE
1)
Module sequence
Fail-safe module VOGI after a volume booster VOGM
End plate VABE as the last module
Impermissible module
combinations
Fail-safe module VOGI and flange module for safety functions VABP
Identical modules
Exception: flange modules for safety functions VABP
Different filter regulating valves PCRI
1) If the maximum number of modules is exceeded, additional measures are required to comply with vibration resistance and shock
resistance.
Tab. 6: Rules for set-up
Exemplary structure
5
4
3
2
1
Fig. 19: Exemplary structure
1
Adapter plate VABA
2
Volume booster VOGM
3
Fail-safe module VOGI
4
Filter regulator PCRI
5
End plate VABE