10.1

Reset to factory settings

NOTICE!

Resetting to the factory settings will lose the current settings.

If required, make a note of these settings before reset.

Reset [rES] restores the factory setting. Press and hold "

v

 + 

V

 + Edit" and then

switch on the device.
The following parameters are then set:

Parameter

Setting/value

x.xx

Permanent display (actual value/setpoint value)

Pr2

(universal control behaviour)

bar

bar

OFS

000

rnG

for 1 MPa type: 10
for 0.6 MPa type: 6
for 0.2 MPa type: 2

Frc

Display shows existing pressure at pressure output (p2)

An

Output: analogue

Eco

OFF

Pin

OFF

Tab. 10 

10.2

Repair

Send the product to the Festo repair service for repair.

11

Technical data

Fig. 5 VPPE-3-1-1/8-2-... p1 = 0.4 MPa

Fig. 6 VPPE-3-1-1/8-6-... p1 = 0.8 MPa

Fig. 7 VPPE-3-1-1/8-10-... p1 = 1.1 MPa

Characteristic values

Design

Proportional-pressure regulator

Characteristic values

Mounting position

As desired, preferably vertical (electronics upward).

Medium

[7:4:4]
Lubricated operation not possible

Pressure regulation range

[MPa]

0.002 … 0.2

0.006 … 0.6

0.01 … 1

Permissible input pressure
(Input pressure p1 min. 0.1
MPa above output pressure
p2)

[MPa]

0.3 … 0.4

0.6 … 0.8

0.6 … 1.1

Standard nominal flow rate

è

 Fig.5 to 

è

 Fig.7

Total leakage when new

[l/h]

<

 5

Ports

G1/8

Nominal width

Pressurisation

[mm]

5

Exhaust

[mm]

2.5

Degree of protection

IP 65 in combination with connector socket according to
accessories

Permissible temperature range

Environment

[°C]

0 … +60

Storage

[°C]

–10 … +60

Medium

[°C]

+10 … +50

Electrical connection

Pin contact M12x1, 5-pin

Permitted supply voltage

24 V DC ± 10%

Setpoint variable input resistance

0 … +10 V/4 … 20 mA
10 kΩ (voltage)/250 Ω (current)

Load actual value output

min. 2 kΩ (voltage)
max. 500 Ω (current)

Residual ripple

[%]

10

Vibration and shock

Vibration

Tested in accordance with DIN/IEC 68/EN 60068
Part 2-6,
Severity level 2

Shock

Tested in accordance with DIN/IEC 68/EN 60068
Part 2-27,
Severity level 2

Power consumption

[W]

max. 4.2

Electromagnetic compatibility

EMC interference emission
and immunity to interfer-
ence

See declaration of conformity

è

 www.festo.com

CE conformity for industrial installations fulfilled

Materials

Housing

Al

Cover

PA

Seals

NBR

Lubrication

silicone-free

Weight

[g]

390

Tab. 11 Characteristic values

Control characteristics

Linearity

1% full scale (FS) at 24 V DC and 25 °C

Hysteresis

Pressure regulation range
0.002 MPa … 0.2 MPa

1% full scale (FS)

Pressure regulation range
0.006 MPa … 0.6 MPa

0.5% full scale (FS)

Pressure regulation range
0.01 MPa … 1 MPa

0.5% full scale (FS)

Reproducibility

0.5% full scale (FS)

Total accuracy

Pressure regulation range
0.002 MPa … 0.2 MPa

1.5% full scale (FS)

Pressure regulation range
0.006 MPa … 0.6 MPa

1.25% full scale (FS)

Pressure regulation range
0.01 MPa … 1 MPa

1.25% full scale (FS)

Temperature coefficient

0.04%/K

Tab. 12 Control characteristics

Содержание VPPE-3-1-1/8 E1 Series

Страница 1: ...t in accordance to IEC EN UL CSA 61010 1 or on a Limited Power Source LPS in accordance to IEC EN UL CSA 60950 1 or IEC EN UL CSA 62368 1 or a Class 2 circuit in accordance to NEC or CEC Electrical data and ambient conditions Supply voltage 24 V DC Max power 4 2 W Rated pressure up to 1 1 MPa Max installation height 2000 m Tab 2 3 Further information Accessories è www festo com catalogue Spare par...

Страница 2: ...s maintained uncontrolled Leakage results in a change of pressure over the long term 1 Connect the VPPE with a setpoint value signal The VPPE has a so called differential input The setpoint signal is applied to the contact pin 2 and pin 4 where the lower potential must be connected to the contact pin 2 and the higher potential to the contact pin 4 Contact pin 2 setpoint value can be connected to c...

Страница 3: ...on option v V 1 x xx v 1 sec in V 1 sec out 2 Pr Pr Pr1 Pr2 Pr3 3 bAr bAr bAr PA PSI 4 OFS 5 rnG 6 Frc 0 00 10 0 V voltage variant 4 00 20 0 mA current variant 7 An An SP O SP SP L HY HY SP H n Lo n Hi n Lo n Hi n Lo n Hi HY n Lo n Hi n Lo n Hi n Lo n Hi 8 Eco OFF OFF 1 999 sec 9 Pin OFF OFF 1 999 back to no 1 Tab 8 7 5 Preparation 8 Operation NOTICE When switching off the VPPE make sure that the ...

Страница 4: ...e of protection IP 65 in combination with connector socket according to accessories Permissible temperature range Environment C 0 60 Storage C 10 60 Medium C 10 50 Electrical connection Pin contact M12x1 5 pin Permitted supply voltage 24 V DC 10 Setpoint variable input resistance 0 10 V 4 20 mA 10 kΩ voltage 250 Ω current Load actual value output min 2 kΩ voltage max 500 Ω current Residual ripple ...

Отзывы: