3. Proportional pressure regulator
3−17
Festo P.BE−MPA−ELECTRONIC−EN en 0804NH
3.1.6
Diagnostic
LED displays
Power LED
Display
installation
Fault treatment
lights up
green
Operating voltage applied
None
off
Operating voltage not applied
Check power supply
Tab.3/13: Power LED of the proportional pressure regulator
Error LED
Display
installation
Fault
number
Fault treat
ment
off
No error
None
lights up red
lower limit exceeded
Output value is less than the para
meterised limit.
or
upper limit exceeded
Output value is greater than the
parameterised limit.
or
fault in parameterising
Parameter lower limit
Parameter upper limit
Upper
Ţ
lower limit value
9
10
24
25
29
·
Check supply
pressure
·
Check the
parameter
ised limit va
lues
flashes red
Undervoltage
5
Check the power
supply
Tab.3/14: Error LED of the proportional pressure regulator