1. MPA pneumatic modules
1−19
Festo P.BE−MPA−ELECTRONIC−EN en 0804NH
1.4.2
Further parameters for electronic module type VMPA...−
D2
−..
For the diagnostic functions of the MPA electronic modules
VMPA1−FB−EM..−
D2
−8 and VMPA2−FB−EM..−
D2
−4, in addition to
those described in section 1.4.1, there are also the following
parameters:
Module parameter: Monitoring the CPX module
Handheld
Function no.
4828 + m * 64 +
0
m = module number (1 ... 47)
Description
Monitoring of the possible faults can be activated or deactivated (suppressed)
for each module independently. Active monitoring causes the following.
The fault is:
displayed via the fault LEDs.
sent to the CPX bus node
Bit
Bit 3: Short circuit in valve coil voltage (V
VAL
)
[Monitor SCV]
Values
Bit 3 Setting:
0 inactive (default)
1 active
[Inactive]
[Active]
Note
Monitoring can also be set for the complete CPX terminal (see CPX system
manual).
Tab.1/9: Parameterising diagnostic message Short circuit in load voltage for valves"
(only with VMPA...−D2−..)
Содержание VMPA-FB-PS Series
Страница 2: ......
Страница 49: ...MPA pressure sensor 2 1 Festo P BE MPA ELECTRONIC EN en 0804NH Chapter 2 Type VMPA FB PS ...
Страница 65: ...Proportional pressure regulator 3 1 Festo P BE MPA ELECTRONIC EN en 0804NH Chapter 3 Type VPPM 6TA ...
Страница 83: ...Technical appendix A 1 Festo P BE MPA ELECTRONIC EN en 0804NH Appendix A ...
Страница 90: ...A Technical appendix A 8 Festo P BE MPA ELECTRONIC EN en 0804NH ...
Страница 91: ...Index B 1 Festo P BE MPA ELECTRONIC EN en 0804NH Appendix B ...
Страница 92: ...B Index B 2 Festo P BE MPA ELECTRONIC EN en 0804NH ...
Страница 96: ...B Index B 6 Festo P BE MPA ELECTRONIC EN en 0804NH ...