Festo VEAB Скачать руководство пользователя страница 3

13

Disposal

ENVIRONMENT!

Send the packaging and product for environmentally sound recycling in accord-
ance with the current regulations 

è

 www.festo.com/sp.

14

Technical data

Characteristic

Specification/value

Design

Proportional-pressure regulator

Mounting position

Any

Compressed air in accordance with
ISO 8573-1:2010 [7:4:4]

Operating medium

Inert gases

Information on the operating
medium

Lubricated operation not possible

CE marking
(Declaration of conformity

è 

www.festo.com/sp)

In accordance with EU-EMC Directive

1)

Degree of protection

IP65 (completely mounted)

Climate class in accordance
with EN 60721

3K3

Nominal operating voltage

[V DC]

24

Operating voltage range

[V DC]

19 … 29

Permissible residual ripple of
operating voltage

[%]

10

Maximum current consump-
tion

[A]

0.08

Maximum signal line length

[m]

<

 30

Inlet pressure 1 (vacuum in connection 3)

VEAB-...-D13-...

[bar]

0 … 2

VEAB-...-D14-...

[bar]

–1

VEAB-...-D15-...

[bar]

0 … 2 bar

VEAB-...-D18-...

[bar]

0 … 5.5

Inlet pressure 1 in connection 1

VEAB-...-D2-...

[bar]

0 … 4

VEAB-...-D7-...

[bar]

0 … 3

VEAB-...-D9-...

[bar]

0 … 6.5

VEAB-...-D12-...

[bar]

0 … 1

Pressure control range

VEAB-...-D2-...

[bar]

0.01 … 2

VEAB-...-D7-...

[bar]

0.005 … 1

VEAB-...-D9-...

[bar]

0.03 … 6

VEAB-...-D12-...

[bar]

0.001 … 0.2

VEAB-...-D13-...

[bar]

–1 … +1

VEAB-...-D14-...

[bar]

–1 … –0.005

VEAB-...-D15-...

[bar]

–0.5 … +0.5

VEAB-...-D18-...

[bar]

–1 … +5

Accuracies

Repetition accuracy

[%]

± 0.4 FS (full scale)

Hysteresis
VEAB-...-D2-...
VEAB-...-D7-...
VEAB-...-D9-...
VEAB-...-D14-...

[%]

£

 0.25 FS (full scale)

Hysteresis
VEAB-...-D12-...
VEAB-...-D13-...
VEAB-...-D15-...
VEAB-...-D18-...

[%]

£

 0.5

Linearity error
VEAB-...-D2-...
VEAB-...-D7-...
VEAB-...-D9-...
VEAB-...-D14-...

[%]

£

 0.5 FS (full scale)

Linearity error
VEAB-...-D12-...
VEAB-...-D13-...
VEAB-...-D15-...
VEAB-...-D18-...

[%]

£

 0.8 FS (full scale)

Analogue output

[%]

2 FS (full scale)

Permissible temperature range

Environment

[°C]

0 … +50

Medium

[°C]

+5 … +50 (non-condensing)

Storage

[°C]

–20 … +70

Setpoint value

Analogue input (current vari-
ant)

[mA]

4 … 20

Analogue input (voltage vari-
ant)

[V]

0 … 10

Characteristic

Specification/value

Input resistance setpoint value

At 4 … 20 mA

[Ω]

250

At 0 … 10 V

[k

W

]

10

Actual value

Analogue output (current
variant)

[mA]

4 … 20

Analogue output (voltage
variant)

[V]

0 … 10

Resistance to vibration/shock resistance (in accordance with IEC 60068)

Information

Explanation of the severity levels (SL)

è

 Tab. 7 Features of severity level (SL)

Vibration (part 2 – 6)

Mounting via through-holes

SL2

Mounting to H-rail, mounting
plate, manifold rail

SL1

Shock (part 2 – 27)

Mounting via through-holes

SL2

Mounting to H-rail, mounting
plate, manifold rail

SL1

Continuous shock (part 2 – 27)

Mounting via through-holes

SL1

Mounting to H-rail, mounting
plate, manifold rail

SL1

Materials

Housing

PA, PAMX

Screws

Steel, hardened and tempered
Steel, galvanised

Seals

NBR

Adapter plate

Wrought aluminium alloy

Weight

Sub-base valve weight

[g]

Approx. 70

In-line valve weight

[g]

Approx. 70

1) The product is intended for industrial use. Outside of industrial environments, e.g. in commercial and

mixed-residential areas, actions to suppress interference may have to be taken.

Tab. 6 General technical data

Features of severity level (SL)

Vibration load

Frequency range [Hz]

Acceleration [m/s

2

]

Deflection [mm]

SL1

SL2

SL1

SL2

SL1

SL2

2 … 8

2 … 8

±3.5

±3.5

8 … 27

8 … 27

10

10

27 … 58

27 … 60

±0.15

±0.35

58 … 160

60 … 160

20

50

160 … 200

160 … 200

10

10

Shock load

Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

SL1

SL2

SL1

SL2

SL1

SL2

±150

±300

11

11

5

5

Continuous shock load

Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

±150

6

1000

Tab. 7 Features of severity level (SL)

Отзывы: