background image

Assembly instructions (en) 

756 749 / 2011-02a 

 

 

 

†‡

 

Manifold sub-base 
VABF-S4-…-S 

Festo AG & Co. KG

 
Postfach 
D-73726 Esslingen 
++49/(0)711/347-0 
www.festo.com 

 

 

1.

 

Parts list 

 

14772d_1 

 

14772d_2 

 

1

  Manifold sub-base (1x) 

VABF-S4-…-S 

2

 Screw 

(2x) 

3

 Seal 

(1x) 

 

Not included in scope of 

delivery: 

4

 Screw 

(2x) 

5

 Cover 

cap 

(1x) 

VAMC-S6-CH 

6

 Solenoid 

valve 

(1x) 

 

VSVA-B-M52-MZD-A…-

1T1L-… 

7

  Manifold sub-base (1x) 

VABV-S4-… 

8

  Blanking plug (2x) 

B-1/4 or B-1/8 

9

 Seal 

(1x) 

VABD-S6-10-…-C 

aJ

  End plate (1x) 

VABE-S6-1RZ-… 

aA

  Blanking plug (1x) 

B-1/4… 

aB

 Screw 

(4x) 

 

The manifold sub-base 

1

 with mounted solenoid valve 

6

 is intended to 

switch the pilot air supply in a valve terminal VTSA. 

 

 

Warning 

Beware of electric shock and uncontrolled movements of components; 

they can result in injuries. 

 

Mount or dismount only in an unpressurised state and ensure power is 

switched off. 

 

Use only the components from this parts list. 

 

 

Note 

In order to avoid functional faults: 

 

Make sure that: 

 

only one manifold sub-base 

1

 is mounted per VTSA; 

 

the manifold sub-base 

1

 is mounted on valve position 0 of the valve 

terminal VTSA; 

 

the manual override of solenoid valve 

6

 is non-detenting, via cover 

cap 

5

 

the correct end plate 

aJ

 for external pilot air and the blanking plug 

aA

 

are mounted on port 14 

 Section 3. 

 

Observe the permitted tightening torques 

 Section 4. 

 

 

Information 

 

Also observe all additional information in the description of pneumatics 

for the valve terminal from Festo. 

2.

 

Mounting of the manifold sub-base 

1

  

 

Information 

After mounting the manifold sub-base 

1

 and the solenoid valve 

6

 the pi-

lot exhaust air is always unducted, despite selecting "ducted exhaust air" 

for the valve terminal, even when the seal on the solenoid valve 

6

 is ro-

tated. 

 

 

14772d_3 

 

As a result, the position of the 

seal at the solenoid valve 

6

 is 

not relevant for the "pilot air 

switch-off" function. 

 

Make sure that the seal 

3

 is 

seated correctly. 

 

Pay attention to the pressed-

in coding pin (A) in order to 

mount the manifold sub-

base 

1

 in the correct posi-

tion. 

 

Fasten the manifold sub-

base 

1

 to the valve terminal 

using the screws 

2

 

Fasten the solenoid valve 

6

 

to the manifold sub-base 

using the screws 

4

 

Insert the blanking plugs 

8

 

into ports 2 and 4 of the 

manifold sub-base 

7

 

14772d_4 

 

 

Mount the cover cap 

5

 on the manual override 

 related assembly instructions. 

 

3.

 

Mounting the end plate 

aJ

 

 

Check whether an end plate 

aJ

 for external pilot air is mounted.  

 

Remove incorrect end plates from the valve terminal, if necessary. 

 

 

14772d_6 

 

For end plate:  

VABE-S6-1RZ-G…/N…: 

 

Make sure that the seal 

9

 is 

seated correctly. 

 

Fasten the end plate 

aJ

 to the 

valve terminal using the 

screws 

aB

 

Screws the blanking plug 

aA

 

into port 14. 

 

14772d_5 

 

For selector end plate 

VABE-S6-1RZ-…-B1: 

 

Observe the relevant assem-

bly instructions. 

 

Put the selector (B) on posi-

tion 3. 

 

Screws the blanking plug 

aA

 

into port 14. 

 

4.

 

Screw sizes and tightening torques M

A

1)

 

 

VABF- 

2

 

[Nm]

4

[Nm] 

8

 

[Nm] 

aA

 

[Nm] 

aB

 

[Nm]

S4-1-S 

M4x12 2 M4 2 G1/4 6.4 

G1/4 7 

+ 40%

M5x16 3 

    

 NPT1/4 

30

2)

 NPT1/4 30

2)

   

 

S4-2-S 

M3x12 1 M3 1 G1/8 4 G1/4 7 

+ 40%

M5x16 3 

    

 NPT1/8 

30

2)

 NPT1/4 30

2)

   

 

 

                                                                            

1)

 Tolerance for non-toleranced tightening torques M

A

 

M

> 1 Nm: ± 10% 

2)

 Hand-tight + max. 2 turns 

aJ

9
aA 

aB

1

aJ 

aB

aA 

1

aJ 

aA

7

1

4

8

3

Отзывы: