Technical specifications (continued) type SPC200-PWR-AIF
Operating voltage pin 2
(internal circuitry)
– nominal value
– tolerance
1)
– residual ripple
– power failure bridging time
– current consumption with:
SPC200-CPU-4
SPC200-CPU-6
24 V DC
-5 %...+25 % (22.8 V ... 30.0 V)
2 %
10 ms
400 mA + current requirement of
components connected to sensor
supply
2)
+ sum of current consumption
on AIF string
3)
600 mA + current requirement of
components connected to sensor
supply
2)
+ sum of current consumption
on AIF string
3)
Protection against electric shock
(protection against direct and indi-
rect contact as per IEC/DIN EN
60204-1)
by means of PELV circuits
(Protective Extra-Low Voltage)
Electromagnetic compatibility
– Interference emitted
– Immunity against interference
Tested as per
DIN EN 61000-6-4 (industry)
4
)
Tested as per
DIN EN 61000-6-2 (industry)
Oscillation and shock
– oscillation
– shock
tested as per DIN/IEC 68 Part 2–6
severity class 1
tested as per DIN/IEC 68 Part 2–27
severity class 2
1)
Observe the tolerance of the modules connected to the axis interface string
2)
Max. 0.5 A can be made available for each I/O module type SPC200-DIO
3)
See technical specifications of the connected modules
4)
The component is intended for industrial use
Eng
li
s
h
SPC200-PWR-AIF
18