SOPA-...
38
Festo – SOPA-... – 2017-09b English
Technical data
SOPA-M
SOPA-C
Supply pressure
[MPa]
0.08…0.16
Max. overload pressure
[bar]
7
Max. overload pressure
[MPa]
0.7
Nominal pressure
[bar]
5
1.2
Nominal pressure
[MPa]
0.5
0.12
Operating medium
Compressed air according to ISO 8573-1:2010 [7:4:4]
Temperature of medium
[°C]
0...+50
Ambient temperature
[°C]
0...+50
Nominal temperature
[°C]
20
Switching output
Switching output
–
SOPA-...-2P
–
SOPA-...-2N
2 x PNP
2 x NPN
Switching function
–
Distance monitoring (Out A/B):
–
Supply pressure monitoring (Out C ):
Threshold value comparator
Window comparator
Switching element function
N/C or N/O contact,
adjustable
Repetition accuracy of switching point
–
Sensing range 30 μm…150 μm
–
Sensing range 20 μm…200 μm
+/–2.5
+/–5
Temperature coefficient
of switching point/10 K
[%]
Typically 2
Switch-on time
See Fig. 19 and Fig. 20
Max. output current
[mA]
100
Max. voltage drop
[V]
1.5
Measured value indicator
Display range In A/In B (distance)
0…400 (dimensionless)
Display range In C (supply pressure)
[bar]
0…2
Display range In C (supply pressure)
[MPa]
0…0.2
Output, additional data
Short circuit protection
Yes (pulsed)
Overload protection
Present
Electronics
Rated operating voltage DC
[V]
24
Operating voltage DC
[V]
22.8…26.4
15.0…30.0
Max. idle current
[mA]
10
50
Reverse polarity protection
For all electrical connections
Electromechanics
Electrical connection
Plug connector M12x1, 4-pin
Max. cable length
[m]
30