4.2
Pneumatic system
1
2
2
1
Control module
2
Sensor modules
Fig. 14
Pneumatic arrangement
1. Insert the tube (outside diameter: 6 mm) into the push-in fittings.
2. Connect the supply port for the measuring nozzle to the corresponding measuring nozzle (
è
Fig. 3).
3. For operation with a control module: Connect the supply port for the operating pressure to the
compressed air source.
For operation without a control module: Connect the supply port for the supply pressure to the
precision pressure regulator.
4. Ensure adequate exhaust at the vent screw connection (
è
Fig. 2) (via vent screw or differential
pressure regulator (LRLL-1/8-QS-6).
Avoiding contamination of the measuring nozzles during downtimes
The vent screw
(
è
Fig. 2) can be removed and this connection used with a deactivated main air supply
and power supply, if necessary, to feed purge air.