Festo SFAM-62 Скачать руководство пользователя страница 8

11

Technical  specifications

SFAM

−1000

−3000

−5000

−M

−T

−M

−T

−M

−T

General  information

Certification

C  tick

CE  symbol(

è

  Conformity  declaration)

In  accordance  with  EU  EMC  directive

Note  on  materials

RoHS−compliant

Input  signal  /  Measuring  element

Measured  variable

Flow,  air  consumption

Direction  of  flow

−L

Unidirectional  P1 

}

  P2

−R

Unidirectional  P1 

{

  P2

Measuring  principle

Thermal

Flow  measuring  range

[l/min]

10 

Ū

  1000

30 

Ū

  3000

50 

Ū

  5000

Operating  pressure

[bar]

Ū

  16

Nominal  pressure

[bar]

6

Operating  medium

Air  quality  class  5:4:3  to  DINISO8573−1

p

g

Nitrogen

Temperature  of  medium

[°C]

0

Ū

50

Ambient  temperature

[°C]

0

Ū

50

Nominal  temperature

[°C]

23

Output  general

 

1)  2)

Accuracy,  zero  point  ±FS

[%]

0.3

Accuracy  range  ±FS

[%]

3

Repeat  accuracy,  zero  point  ±FS

[%]

0.2

Repeat  accuracy,  zero  point  ±FS

[%]

0.8

Temperature  coefficient  range  ±FS/K

[%]

  0.1

Pressure−dependence  range  ±FS/bar

[%]

0.5

Switching  output

Switching  output

2x  PNP  or  2x  NPN,  adjustable

Switching  symbols

Window  comparator  or  threshold  value
comparator,  adjustable

Switching  element  function

N/C  or  N/O  contact,  adjustable

Switch−on  time

Adjustable  (factory  setting:  approx.  60ms)

Switch−off  time

Adjustable  (factory  setting:  approx.  60ms)

Max.  output  current

[mA]

100

Voltage  drop

[V]

Max.  1.5

Inductive  protective  circuit

Adapted  to  MZ,  MY,  ME  coils

Analogue  output

Characteristic  flow  rate  curve

[l/min]

0

Ū

1000

0

Ū

3000

0

Ū

5000

Output  characteristics  curve,  current

[mA]

4

Ū

20

Output  characteristics  curve,  voltage

[V]

0

Ū

10

Rise  time

[ms]

15,  30,  60  (factory  setting),  125,  250,  500,  999
adjustable

Max.  load  resistance  at  current  output

[Ohm]

500

Min.  load  resistance  at  voltage  output

[kOhm]

10

Output,  other  specifications

Protection  against  short  circuit

Yes

Protection  against  overloading

Yes

Electronics

Operating  voltage  range  DC

[V]

15

Ū

30

Protection  against  polarity  reversal

For  all  electrical  connections

Electromechanics

Electrical  connection

Straight  plug,  M12x1,  5−pin

Max.  length  of  connecting  cable

[m]

<

  10

SFAM

−1000

−3000

−5000

−M

−T

−M

−T

−M

−T

Mechanics

Mounting  position

Horizontal  ±5

Pneumatic  connection

G1/2

G1/2

G1/2

NPT1/2

NPT1/2

NPT1/2

Product  weight

[g]

600

1100

600

1100

600

1100

Housing  material

Reinforced  polyamide,  die−cast  aluminium

Display  /  operation

Type  of  display

Illuminated  LCD,  blue

Presentable  units

l/min,  scfm,
l,  m

3

,  scf

Setting  range,  threshold
value,  flow

1  %  FS 

Ū

  100  %  FS

Setting  range,  threshold

[l]

Ū

  19999

10 

Ū

  19999

15 

Ū

  19999

g

g ,

value,  consumption  impulse

[m

3

]

Ū

  19999

[scf ]

0.1 

Ū

  1999.9

0.4 

Ū

  1999.9

0.5 

Ū

  1999.9

Hysteresis  setting  range

0  %  FS 

Ū

  90  %  FS

Immission  /  emission

Storage  temperature

[°C]

20 

Ū

  +80

Protection  class

IP65

Pressure  drop

[mbar]

<

  100

Protection  type

III

1)

Accuracy  under  rated  conditions  (6bar,  23°C,  and  horizontal  mounting  position)

2)

%FS=%  of  the  measurement  range  limit  value  (full  scale)

Fig.20

Air  flow  measuring  range

1)

  qn  as  a  function  of  supply  pressure  p

specific  flow  rate

1)

From  an  operating  pressure  of  5bar  upwards  measured  values  can  be  determined  throughout  the  entire
measuring  range  by  the  flow  sensor  with  the  specific  accuracy.  At  an  operating  pressure  below  5bar  the
measuring  range  shrinks  with  the  specified  accuracy  shown  in  the  graph.

Fig.21

Characteristic  curve  for  the  analogue  output

Option

Factor

Unit

Analogue  output

p

0V  or  4mA

10V  or  20  mA

lower  limit

upper  limit

Standard  conditions  in  accordance  with  DIN  1343  (1.01325bar,  0°C)

OFF

1

[l/min]

0

1000

3000

5000

[scfm]

0

35.31

105.9

176.6

Standard  conditions  in  accordance  with  ISO  2533  (1.01325bar,  15°C)

1

1.055

[l/min]

0

1055

3165

5275

[scfm]

0

37.25

111.8

186.3

Standard  conditions  in  accordance  with  ISO  6358  (1bar,  20°C)

2

1.09

[l/min]

0

1090

3270

5450

9

[scfm]

0

38.49

115.5

192.4

Fig.22

Содержание SFAM-62

Страница 1: ...tion SFAM T or combination with service units of the MS series SFAM M Measurement is carried out by means of a thermal procedure The amount of heat which is drawn from a heated surface of the sensor b...

Страница 2: ...ed to the connection where the sieve cartridge on type SFAM M or the starting stretch on type SFAM T is situated The air mass flow is taken from the opposite connection In order to maintain the accura...

Страница 3: ...pressing Edit button for 3 seconds or passage of a monitoring time timeout 1 Switch on the operating voltage The SFAM is in RUN mode 2 Check the settings of the SFAM chapter 5 3 SHOW mode 5 1 Symbols...

Страница 4: ...e CI switching element function no nc closer opener minimum flow value F Lo Flow Low In order to delete the minimum value press the EDIT button briefly maximum flow value F Hi Flow High In order to de...

Страница 5: ...Hy flashes 8 Set the value for the hysteresis Hy with the A B buttons 9 Press the Edit button to confirm the set value no or nc flashes 10 Select the switching element function no nc with the A B but...

Страница 6: ...oothing to d6 maximum smoothing With increasing smoothing the switch on switch off time of the switch outputs rises With d OFF the response time of the analogue output equals the set response time Sig...

Страница 7: ...be compared e g operating volume flow amount supplied by a compressor measured values of a flow sensor from another manufacturer refer to the same basic conditions After the power supply is switched...

Страница 8: ...Electronics Operating voltage range DC V 15 30 Protection against polarity reversal For all electrical connections Electromechanics Electrical connection Straight plug M12x1 5 pin Max length of connec...

Отзывы: