Flow  sensor  SFAM−62

Festo  AG  &  Co.  KG

Postfach
D−73726  Esslingen
++49/711/347−0
www.festo.com

Operating  instructions

743  859
0902NH

Original:  de

Note

Installation  and  commissioning  may  only  be  performed  in  accordance  with  these
instructions  by  technicians  with  appropriate  qualifications.

Note

The  product  is  suitable  for  use  only  for  industrial  purposes.
In  residential  areas,  measures  for  radio  interference  suppression  may  be
necessary.  It  is  not  suitable  for  commercial  invoicing,  such  as  for  measurement
of  air  consumption  in  public  utilities.

1

Product  description

1.1 Overview

6

SFAM−

Ū

−M

1

2
3
4
5

7

6

SFAM−

Ū

−T

8

5

1

Display

2

B  button

3

Edit  button

4

A  button

5

Plug  for  electrical  connection

6

Supply  port

7

Sieve  cartridge

8

Starting  stretch

Fig.1

1.2 Features

Feature

Order
code

Design

Basic  type

SFAM

Flow  sensor

Grid  dimension

−62

62mm

Flow  measuring  range

−1000

max.  1000l/min

g

g

−3000

max.  3000l/min

−5000

max.  5000l/min

Flow  input

L

unidirectional  from  the  left

p

R

unidirectional  from  the  right

Type  of  fastening

−M

manifold  assembly

yp

g

−T

thread  fitting

−W

additional  wall  mounting

Pneumatic  connection

G12

G

½

N12

½

"  NPT

Electrical  output

−2SA

2x  PNP  or  NPN,  1  analogue  output  4 

Ū

  20  mA

p

−2SV

2x  PNP  or  NPN,  1  analogue  output  0 

Ū

  10  V

Electrical  connection

−M12

plug  M12x1,  5−pin,  A−coded

Electrical  accessories 

1)

−2.5S

connecting  cable,  straight  socket,  cable  length  2.5m

−5S

connecting  cable,  straight  socket,  cable  length  5m

−2.5A

connecting  cable,  angled  socket,  cable  length  2.5m

−5A

connecting  cable,  angled  socket,  cable  length  5m

1)

Included  in  the  scope  of  delivery.

Fig.2

2

Function  and  application

The  SFAM  is  designed  to  monitor  changes  in  flow  and  air  consumption

 

for  suitable

media  in  pipe  systems  or  end  devices  in  industry;  suitable  media 

è

chapter  11

Technical  specifications.  The  structural  design  enables  autonomous  operation
(SFAM−

Ū

−T)  or  combination  with  service  units  of  the  MS  series  (SFAM−

Ū

−M).

Measurement  is  carried  out  by  means  of  a  thermal  procedure.  The  amount  of  heat,
which  is  drawn  from  a  heated  surface  of  the  sensor  by  the  medium  flowing  through
it,  is  calculated  here.  Through  the  amount  of  heat  removed,  the  flow  or  accumu
lated  air  consumption  is  determined  and  shown  on  the  display.  The  connection  to
higher−level  systems  is  made  via  2  binary  outputs  (OutA/B)  and  one  analogue
output  (OutC).  Switching  points  can  be  set  for  both  binary  outputs.  For  flow
measurement,  switching  points  are  possible  for  both  binary  outputs,  and  for  accu
mulated  air  consumption  measurement  a  consumption  switch  impulse  for  outputA
(OutA).  The  combination  of  accumulated  air  consumption  measurement  (OutA)
and  flow  measurement  (OutB)  is  possible.  The  flow  rate  value  is  passed  on  via  the
analogue  output.

3

Conditions  for  the  safe  use  of  the  product

Warning

Depending  on  the  functioning  of  the  machine/system,  manipulation  of  signal
states  may  cause  serious  personal  injury.
· Note  that  if  the  switching  status  of  the  outputs  is  modified  in  Edit  mode,  the

new  status  will  be  effective  immediately.

· Activate  the  password  protection  (security  code)  in  order  to  prevent  the

unintentional  change  by  unauthorized  third  parties 

è

chapter5.4,  section

Security  code.

Warning

Use  of  the  product  in  combination  with  prohibited  media  can  result  in  personal
injury.
· Do  not  use  the  product  in  conjunction  with  inflammable  gases,  corrosive

gases,  oxygen  etc.  The  product  is  intended  only  for  measuring  the  flow  of
media,  which  are  listed  as  suitable  in  the  specifications  chapter  11.

Important

Condensation  water,  oil  mist,  foreign  matter  and  other  dirt  in  the  compressed  air
can  damage  the  product  and  cause  incorrect  measurements  and  functional
disorders.
· Make  sure  that  the  specified  air  quality  class  is  maintained  for  the  operating

medium 

è

chapter  11  Technicalspecifications.

Note

Improper  handling  can  result  in  malfunctions.
· Make  sure  that  the  following  specifications  are  always  observed:

Содержание SFAM-62

Страница 1: ...tion SFAM T or combination with service units of the MS series SFAM M Measurement is carried out by means of a thermal procedure The amount of heat which is drawn from a heated surface of the sensor b...

Страница 2: ...ed to the connection where the sieve cartridge on type SFAM M or the starting stretch on type SFAM T is situated The air mass flow is taken from the opposite connection In order to maintain the accura...

Страница 3: ...pressing Edit button for 3 seconds or passage of a monitoring time timeout 1 Switch on the operating voltage The SFAM is in RUN mode 2 Check the settings of the SFAM chapter 5 3 SHOW mode 5 1 Symbols...

Страница 4: ...e CI switching element function no nc closer opener minimum flow value F Lo Flow Low In order to delete the minimum value press the EDIT button briefly maximum flow value F Hi Flow High In order to de...

Страница 5: ...Hy flashes 8 Set the value for the hysteresis Hy with the A B buttons 9 Press the Edit button to confirm the set value no or nc flashes 10 Select the switching element function no nc with the A B but...

Страница 6: ...oothing to d6 maximum smoothing With increasing smoothing the switch on switch off time of the switch outputs rises With d OFF the response time of the analogue output equals the set response time Sig...

Страница 7: ...be compared e g operating volume flow amount supplied by a compressor measured values of a flow sensor from another manufacturer refer to the same basic conditions After the power supply is switched...

Страница 8: ...Electronics Operating voltage range DC V 15 30 Protection against polarity reversal For all electrical connections Electromechanics Electrical connection Straight plug M12x1 5 pin Max length of connec...

Отзывы: