14
Festo — CPX-AP-A-PN-M12 — 2022-07
Diagnostics and fault clearance
ID hex (dec)
Message
Description
08 | 01 | 0133
(134283571)
AP master process
data input watchdog
timed out
Remedy
–
Adjust cycle time and watchdog parameter.
–
Restart AP system.
–
Check wiring.
Diag-
nostic
status
Error
08 | 01 | 0134
(134283572)
AP master toggle bit
error
A module did not mirror the toggle bit in the process data
Remedy
–
Adjust cycle time and toggle timeout
parameter.
–
Restart AP system.
–
Check wiring.
Diag-
nostic
status
Error
08 | 01 | 013A
(134283578)
Multiple AP Master
detected
Another AP Master with higher priority was recognized.
Remedy
–
Check AP configuration. Only one AP Bus
Interface is allowed
–
Restart AP System
Diag-
nostic
status
Error
08 | 01 | 013B
(134283579)
System Startup failed
(emergency mode)
The AP system startup failed. The AP system is in emer-
gency mode.
Remedy
–
Check for latest firmware versions
–
Restart AP system
Diag-
nostic
status
Error
08 | 01 | 013C
(134283580)
Topology detection
failed
Topology detection failed
Remedy
–
Check for latest firmware versions
–
Restart AP system
Diag-
nostic
status
Error
08 | 01 | 01AD
(134283693)
System state change
to OPERATION failed
The AP device did not change the system state from CON-
FIGURATION to OPERATION.