background image

(V)PE-...-...(SW )

Festo (V)PE-...-...(SW) 2017-05c English

11

Type

(V)PE-...

Maximum switching frequency

[Hz]

1

CE marking symbol (see conformity declaration)

as per EU low voltage directive

Fig. 17

Product-specific specifications (V)PE-... without (V)PE-....-SW

Typ

PE-PK-4

PE-PK-
3x2-2N

PE-
1/8-1N

PE-
1/8-2N

VPE-
1/8

VPE-
1/8-2N

Part no.

7470

13691

6217

7860

12592

12594

Operating pressure

[bar]

0 ... 0,25

0 ... 8

0 ... -0,95

Switch-on point

[bar]

≤ 0,08

≤ 2

 -0,25 

 0,05

Switch-off point

[bar]

≥ 0,01

≥ 0,5

≤ -0,1

Overload pressure
(brief, static)

[bar]

max. 8

max. 12

max. 1

Rated operating
voltage (V

b

)

[V]

AC/DC 250

Rated operating cur­
rent (with V

b

)

[A]
[A]

– ohmic load
– inductive load

at AC 250 V
6
2

at DC 250 V
0,25
0,1

Use category

– ohmic load
– small electromagnetic load

AC 12/DC 12
AC 14/DC 13

Switching output
(DC voltage)

[A]
[A]
[A]

Voltage [V DC]:
– resistor load
– inductive load
– bulb load

12
6
6
3

24
6
6
2

60
1
0,5
0,6

110
0,5
0,2
0,5

220
0,25
0,1
0,25

Protection class

(as per EN 60 529) IP00, IP20 with protective cap type SPE-B

Materials
– Housing
– Connections
– Diaphragm
– Switching contact

PET/POM/St
CuZn 
CR
Ag

PA/GD-AL/St/PET
CuZn
TPE-U(PU)
Ag

PET/POM/St
CuZn
CR
Ag

Fig. 18

Содержание PE-1/8-1N

Страница 1: ...en Operating instructions Pressure vacuum switch V PE 1 8 SW PE PK SW 8068554 2017 05c 8068556...

Страница 2: ...2017 05c 2 Original instructions Symbols Fitting and commissioning to be carried out by qualified personnel only in accordance with the operating instructions Warning Caution Please note Antipollution...

Страница 3: ...tions 1 2 3 4 5 6 1 Compressed air or vacuum connection connecting thread G 1 8 with V PE 1 8 tubing connection with PE PK 2 Screw terminals for electrical connection 3 Sub base for mounting frame 4 T...

Страница 4: ...8 1N Screw terminals VPE 1 8 SW G1 8 1N Cables VPE 1 8 2N G1 8 2N Screw terminals VPE 1 8 2N SW G1 8 2N Cables Fig 2 Overpressure types Compressed air connection Standard length for fitting onto moun...

Страница 5: ...lly open or changeover switch It has been designed for converting pneumatic pressure values into electri cal signals which are used for control or monitor functions 4 Conditions of use Please note Inc...

Страница 6: ...tting Mechanical components S Select the suitable fastening method a by means of through holes 4 in the housing or b by fitting into the following mounting frames NRRQ 1N for V PE 1N PE PK 4 NRRQ 2N f...

Страница 7: ...ted in accordance with IP 20 as per EN 60529 A protective cap as per Accessories see section 9 is required here S Wire the V PE as follows Connection Screw ter minal see Fig 10 Cable co lours PE VPE I...

Страница 8: ...break the hooks off 6 Commissioning S Switch on the operating voltage S Pressurize the compressed air connection with the pressure required as the switching pressure or evacuate the vacuum required as...

Страница 9: ...ng the protective cap Type see section 9 Accessories S Proceed as follows 1 Carefully press hook A outwards do not break off 2 Press hook B 3 Pull the protective cap apart S Disconnect the relevant co...

Страница 10: ...ply correct operating voltage V PE operated with non per mitted medium Replace V PE and operate only with compressed air vacuum Outputs no longer switch back V PE defective Return V PE to Festo Fig 16...

Страница 11: ...1 Overload pressure brief static bar max 8 max 12 max 1 Rated operating voltage Vb V AC DC 250 Rated operating cur rent with Vb A A ohmic load inductive load at AC 250 V 6 2 at DC 250 V 0 25 0 1 Use c...

Страница 12: ...erating voltage Vb V AC DC 250 Rated operating cur rent with Vb A A ohmic load induktive Last bei AC 250 V 5 2 bei DC 250 V 0 25 0 03 Use category ohmic load small electromagnetic load AC 12 DC 12 AC...

Страница 13: ...V PE SW Festo V PE SW 2017 05c 13...

Страница 14: ...zation is prohibited Offenders will be liable for damages All rights re served in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG Ruiter Stra e 82 73734 E...

Отзывы: