6.2
Pin allocation table
6.2.1
Digital terminal
I/O
Reference
designation
Designation
Terminal
SysLink
Pin
SysLink
Wire color
I0
-TF1
Switch point comparator, level reached, ultrasonic sensor BL1 Tank VE2
9
13
Gray-pink
I1
-BG2
Capacitive proximity switch, upper limit of the storage tank VE1
10
14
Red-blue
I2
-BG3
Capacitive proximity sensor, lower limit of the storage tank VE1
11
15
White-green
I3
-BG4
Diffuse light sensor, bottle at the beginning of the conveyor
12
16
Brown-green
I4
-BG5
Diffuse light sensor, bottle at the filling position
13
17
White-
yellow
I5
-BG6
Diffuse light sensor, bottle at the end of the conveyor
14
18
Brown-
yellow
I6
15
19
White-gray
I7
-KF10
Overflow alarm of the relay contact, collection error
16
20
Gray-brown
Q0
-MA1
Motor pump PL1 ON, conveying into the filling container
1
1
White
Q1
-MB2
Solenoid valve V403 OPEN, filling bottle
2
2
Brown
Q2
-MA31 / -
MA32
Conveyor motors ON, bottle transport forward
3
3
Green
Q3
-MB4
Activate the separator, separate the bottle
4
4
Yellow
Q4
-MA5
Motor PL2 pump ON, conveying to the next station
5
5
Gray
Q5
6
6
Pink
Q6
7
7
Blue
Q7
8
8
Red
24 V A
24 V power supply for outputs
24 VA
9+10
Black
24 V B
24 V power supply for inputs
24VB
21+22
White-pink
GND A
0 V power supply for outputs
GND A
11
Brown-pink
GND A
0 V power supply for outputs
GND A
12
Purple
GND B
0 V power supply for inputs
GND B
23+24
White-blue
Note
Cable jumpers are connected from emergency off to bit 1.5 on all preferred PLC versions.