4. Commissioning
4−17
Festo P.BE−MPA−EN en 0502b
4.5.2
Operating states of the pneumatic system
The following conditions should be fulfilled, in order that the
desired pneumatic operating states listed below can be
achieved:
Desired pneuma
tic operating sta
tus
Prerequisites
Remarks
free of leakage
tubing connected with care
closed−loop regulated auxiliary
pilot air
fast reaction
sufficient pressure supply via pres
sure supply points
·
Exhaust the MPA valve terminal via
all the exhaust plates or via the
large surface−mounted silencer
faultless
Non−return valves in common ex
haust line
This applies when several systems
with centrally ducted exhaust are
used
two or more pressure
zones
Limiting the pressure zones by
means of sheet seals with blocked
channels
subsequent conversion possible (see
chapter 5)
Vacuum or low−pres
sure operation
externally supplied closed−loop regu
lated auxiliary pilot air (3 ... 8 bar)
Vacuum/low−pressure operation
not with 3/2−way valves
EMERGENCY STOP of
pressure zones
Guaranteeing the controller function
for the auxiliary pilot air despite the
complete supply being switched off
The controller regulates the auxiliary
pilot air of all the valve plates on an
MPA valve terminal
Slow start−up after
EMERGENCY STOP
If there are control signals, the auxi
liary pilot air must have a pressure of
3 ... 3...10 bar immediately after
being switched on
Table4/9:
Pneumatic operating states
Содержание MPA-FB Series
Страница 2: ......
Страница 4: ...Contents and general instructions II Festo P BE MPA EN en 0502b...
Страница 8: ...Contents and general instructions VI Festo P BE MPA EN en 0502b...
Страница 17: ...Summary of components 1 1 Festo P BE MPA EN en 0502b Chapter 1...
Страница 30: ...1 Summary of components 1 14 Festo P BE MPA EN en 0502b...
Страница 31: ...Fitting 2 1 Festo P BE MPA EN en 0502b Chapter 2...
Страница 47: ...Installation 3 1 Festo P BE MPA EN en 0502b Chapter 3...
Страница 55: ...3 Installation 3 9 Festo P BE MPA EN en 0502b 1 2 3 Fig 3 2 Disconnecting the tubing...
Страница 79: ...Commissioning 4 1 Festo P BE MPA EN en 0502b Chapter 4...
Страница 96: ...4 Commissioning 4 18 Festo P BE MPA EN en 0502b...
Страница 97: ...Diagnosis and error treatment 5 1 Festo P BE MPA EN en 0502b Chapter 5...
Страница 139: ...Technical appendix A 1 Festo P BE MPA EN en 0502b Appendix A...
Страница 151: ...Accessories B 1 Festo P BE MPA EN en 0502b Appendix B...
Страница 161: ...Index C 1 Festo P BE MPA EN en 0502b Appendix C...
Страница 162: ...C Index C 2 Festo P BE MPA EN en 0502b Contents C Index C 1...