Contact allocation table
Contact allocation EMERGENCY-STOP plug
EMERGENCY-STOP terminal at the
PLC board (XN)
EMERGENCY-STOP
1 (bridged)
1
24 V
EMERGENCY-STOP
2 (bridged)
2
NA 24V (XMA2)
contact extension
3
3 (bridged)
contact extension
4
4 (bridged)
5.2
EMERGENCY STOP
plug/terminal
Note
The Emergency-Stop signal additionally is connected to E 1.5 (XMG1 Syslink)!