Festo FEC-FC640 Скачать руководство пользователя страница 1

 

SPS-Board 
FESTO 
FEC

®

 Standard 

Handbuch 
 
PLC board 
FESTO 
FEC

®

 standard 

Manual 

 

 

 

668858 DE/EN 
07/05 

Содержание FEC-FC640

Страница 1: ...SPS Board FESTO FEC Standard Handbuch PLC board FESTO FEC standard Manual 668858 DE EN 07 05...

Страница 2: ...ludes any liability for damage or injury caused to trainees the training company and or any third party which may occur if the system is in use for purposes other than purely for training unless the s...

Страница 3: ...usg nge ________________________________________________ 10 3 6 NOT AUS Funktion_____________________________________________ 10 4 Inbetriebnahme mit MPS ______________________________________ 11 4 1...

Страница 4: ...outputs________________________________________________ 26 3 6 EMERGENCY STOP function______________________________________ 26 4 Commissioning with MPS ______________________________________ 27 4 1 C...

Страница 5: ...r Aus und Weiterbildung wurde die SPS in eine didaktische Umgebung im Festo Didactic MPS System integriert Die digitalen Ein und Ausg nge sind auf zwei SysLink Kabel IEEE 488 verdrahtet Die Pin Belegu...

Страница 6: ...herheitstechnisch einwandfreiem Zustand St rungen die die Sicherheit beeintr chtigen k nnen sollten beim Schulungsbetrieb nicht erzeugt werden und sind umgehend zu beseitigen Beachten Sie im Interesse...

Страница 7: ...gesteckter Br cke XN 2 CPU IPC FEC Standard Typ FC640 3 24 V Anschlusskabel mit 4 mm Sicherheitsstecker 4 Anschlusskabel mit SysLink Stecker zum Bedienpult XMG1 5 Anschlusskabel mit SysLink Stecker zu...

Страница 8: ...g nge 16 x digitale Ausg nge 2 x serielle Schnittstellen 1 x Ethernet 10 Base T Schnittstelle Das SPS Board wird ber RS 232 Ethernet Schnittstelle mit dem PC verbunden und mit der Programmiersoftware...

Страница 9: ...g Durch das E A Datenkabel wird das EasyPort mit Betriebsspannung versorgt Deshalb darf keine separate Spannungsversorgung angeschlossen werden Die Simulationsbox Sie simuliert Eingangssignale und zei...

Страница 10: ...en und kann zur besseren Handhabung herausgenommen werden 3 4 Einbauweise Die digitalen Ein und Ausg nge sind auf zwei SysLink Stecker IEEE 488 verdrahtet Die Pin Belegung entspricht der SysLink Schni...

Страница 11: ...erminals der Station 2 SPS Board Bedienpult Stecken Sie den Stecker XMG1 des SPS Boards in die Buchse XMG1 des Bedienpults 3 SPS Board Netzger t Stecken Sie die 4 mm Sicherheitsstecker in die Buchsen...

Страница 12: ...Inbetriebnahme mit MPS 12 Festo Didactic GmbH Co 668858...

Страница 13: ...0 1 2 A 1 1 2 A 0 2 3 A 1 2 3 A 0 3 4 A 1 3 4 A 0 4 5 A 1 4 5 A 0 5 6 A 1 5 6 A 0 6 7 A 1 6 7 A 0 7 8 A 1 7 8 IN E 0 0 13 E 1 0 13 E 0 1 14 E 1 1 14 E 0 2 15 E 1 2 15 E 0 3 16 E 1 3 16 E 0 4 17 E 1 4...

Страница 14: ...f SPS Board XN NOT AUS 1 gebr ckt 1 24 V NOT AUS 2 gebr ckt 2 NA 24V XMA2 Kontakt Erweiterung 3 3 gebr ckt Kontakt Erweiterung 4 4 gebr ckt 5 2 NOT AUS Stecker Klemme Hinweis Das NOT AUS Signal wird z...

Страница 15: ...rung Schnittstellen SysLink Kabel f r Anschluss Station Kabel f r Anschluss Bedienpult Br cke f r NOT AUS Abmessungen H he 400 mm Breite 340 mm Tiefe 300 mm Gewicht ca 5 kg Schutzart IP 20 bersicht de...

Страница 16: ...rom Ausgang digital 24 V DC max 400 mA Maximaler Gruppenstrom Ausgang 3 2 A Maximale Schaltfrequenz Ausgang 1 kHz Merker Z hler Zeiten 10000 256 256 Arbeitsspeicher 512 kByte SRAM Remanente Daten 30 k...

Страница 17: ...ie am Ende dieses Handbuchs Zus tzlich finden Sie elektrische Schaltpl ne zu den SPS Boards auf der Technische Unterlagen CD ROM der MPS Station en oder im Internet unter der Adresse http www festo di...

Страница 18: ...Anhang 18 Festo Didactic GmbH Co 668858...

Страница 19: ...uts________________________________________________ 26 3 6 EMERGENCY STOP function______________________________________ 26 4 Commissioning with MPS ______________________________________ 27 4 1 Cable...

Страница 20: ...Contents 20 Festo Didactic GmbH Co 668858...

Страница 21: ...ted into a didactic environment in the Festo Didactic Modular Production System MPS for use in vocational and further training The digital inputs and outputs are wired up to two SysLink plugs IEEE 488...

Страница 22: ...PLC boards are to be used only for its intended purpose and in an absolutely safe conditions Faults impairing safety must be rectified immediately For your own safety please follow the safety notes b...

Страница 23: ...slotted jumper XN 2 CPU IPC FEC standard type FC640 3 24 V connecting cable with 4 mm safety plugs 4 Connecting cable with SysLink plug to the control console XMG1 5 Connecting cable with SysLink plug...

Страница 24: ...2 x digital inputs and 16 x digital outputs 2 x seriell interfaces 1 x Ethernet 10 Base T interface The PLC is connected to the PC via RS 232 Ethernet interface on the CPU and programmed using the FST...

Страница 25: ...ignals of the PLC For digital signals you need Digital simulation box Order No 170643 Attention The simulation box does not need to be connected to a separate voltage supply if this cable is used sinc...

Страница 26: ...sLink interface of the MPS from Festo Didactic 3 5 Inputs outputs The two sockets marked with EMERGENCY STOP are bridged with the short circuit plug provided in order to provide the voltage supply to...

Страница 27: ...terminal of the station 2 PLC board control console Plug the XMG1 plug of the PLC board into the XMG1 socket of the control console 3 PLC board power supply unit Plug the 4 mm safety plugs into the so...

Страница 28: ...Commissioning with MPS 28 Festo Didactic GmbH Co 668858...

Страница 29: ...1 2 A 1 1 2 A 0 2 3 A 1 2 3 A 0 3 4 A 1 3 4 A 0 4 5 A 1 4 5 A 0 5 6 A 1 5 6 A 0 6 7 A 1 6 7 A 0 7 8 A 1 7 8 IN E 0 0 13 E 1 0 13 E 0 1 14 E 1 1 14 E 0 2 15 E 1 2 15 E 0 3 16 E 1 3 16 E 0 4 17 E 1 4 17...

Страница 30: ...he PLC board XN EMERGENCY STOP 1 bridged 1 24 V EMERGENCY STOP 2 bridged 2 NA 24V XMA2 contact extension 3 3 bridged contact extension 4 4 bridged 5 2 EMERGENCY STOP plug terminal Note The Emergency S...

Страница 31: ...able for connection to station 1 x cable for connection to console 1 x strap for connection to EMERGENCY STOP Dimensions Height 400 mm Width 340 mm Depth 300 mm Weight Approx 5 kg Protection classific...

Страница 32: ...tage current digital 24 V DC max 400 mA Maximum group current outputs 3 2 A Maximum switching speed outputs 1 kHz Flags Counters Timers 10000 256 256 Main Memory 512 kByte SRAM Remanent data 30 kByte...

Страница 33: ...nd at the end of this manual Additionally electrical circuit diagrams for the PLC boards can be found on the Technical details CD ROM of the MPS station s or in internet at the address http www festo...

Страница 34: ...Appendix 34 Festo Didactic GmbH Co 668858...