Festo EPCS-BS Скачать руководство пользователя страница 5

Size

32

45

60

Spindle pitch

[mm/re-
v]

3

8

3

10

5

12

Max. logic current consump-
tion

[mA]

300

1) Maximum value for Speed In/Speed Out at level 10
2) Maximum value for force at level 10
3) The force is controlled and evaluated by regulating the motor current. Depending on the mechanism of the

drive, a linear force can be determined from the level of current measured. The target is set as a percent-
age of the rated motor current and may differ from the actual force at the electric cylinder. In the case of
low set force levels, the influence of friction in the system on the running behaviour and the actual force on
the electric cylinder must also be taken into account.

4) Distance (MechIn –LimIn or MechOut –LimOut)

Tab. 6 Technical Data EPCS-BS

Содержание EPCS-BS

Страница 1: ... torque of the motor into a feed force The linear movement of the piston rod is guided by the guide in the guide ring 4 3 System Overview 1 PELV fixed power supply for load voltage 2 PELV fixed power supply for logic voltage 3 Application software 4 PC or Laptop 5 Controller or IO Link master 6 Electric cylinder unit EPCS BS Fig 1 System Overview Items 1 5 are not in the scope of delivery 4 3 1 Pr...

Страница 2: ...touch metallic housing parts After the power supply is switched off let the device cool down to room tem perature A new homing is only necessary if the reference end position Ref or the useful range is changed When homing the Start Press Position PosStart Press is equated with the new end position LimOut 8 1 Commissioning DIO Operation digital I O Preparation 1 Check the mounting of the drive syst...

Страница 3: ...oming movement MovRef StartRef PosAct è LimIn è LimOut press Run Start Press movement Start Stop and save Start Press Position PosStart Press Save press Execute Demo Run Start Stop Lock pushbutton actuators Lock HMI press and hold for 3 s or no push button actuator input for 15 s Fig 7 HMI menu 9 4 Homing During homing the positions of the mechanical stops MechIn MechOut are determined in order to...

Страница 4: ...atingè parameter Quit Error 0x0029 3 or 0x0107 0 The first error that occurred is always displayed Fig 8 Display of diagnostic messages example Error code Description LED LED displays Event code hex dec C Q Open Parameter IO Link Warning z Warnings1 Lights yel low z z 0x Error z Common device error è Contact Festo 0x1000 0x000F 15 I2t monitoring output stage error 0x1805 0x0016 22 Logic voltage un...

Страница 5: ...e mechanism of the drive a linear force can be determined from the level of current measured The target is set as a percent age of the rated motor current and may differ from the actual force at the electric cylinder In the case of low set force levels the influence of friction in the system on the running behaviour and the actual force on the electric cylinder must also be taken into account 4 Di...

Отзывы: