ELFA-KF/-RF
14
Festo – ELFA-KF/-RF – 2019-05d English
11
Fault clearance
Malfunction
Possible cause
Remedy
Squeaking
noises, vibrations
or the axis is not
running smoothly.
Tensions
Install axis without tension,
Observe evenness of the bearing surface:
(
è
Change arrangement of the tool/payload.
Align axis so it is exactly parallel to the second
axis.
Alter the travel speed.
Insufficient lubrication at
guide
Lubricate the axis (
è
Guide is defective.
Send axis to Festo or contact the local Festo
service.
Wear on guide or band
reverser
Slide does not
move.
Loads are too high.
Reduce load mass/torques.
Mounting screws for the
payload are too long
Comply with the max. screw-in depth
(
è
5.1.2 Mounting attachment components).
Slide travels over
end position.
Proximity sensor does not
switch.
Check proximity sensor, connections and
controller.
Cover band has
waves.
Wear on band reverser
Retension the cover band
(
è
Replace the band reverser and cover band
(
è
www.festo.com/spareparts).
Oil leak between
profile housing
and cover.
Oil accumulator for ELFA-RF
is completely saturated.
Replace oil accumulator.
Tab. 4