background image

(en) Operating 
instructions

Pressure booster

DPA

8080164
2017-07e
[8080166]

Содержание DPA-100-10

Страница 1: ...en Operating instructions Pressure booster DPA 8080164 2017 07e 8080166...

Страница 2: ...on of the original instructions Symbols Installation and commissioning may only be per formed in accordance with these instructions by technicians with appropriate qualifications Warning Caution Note...

Страница 3: ...5 6 7 4 1 3 2 6 5 7 8 8 1 Pneumatic connection 1 for input pressure 2 Pneumatic connection 2 for output pressure 3 Pneumatic connection 3 for exhaust air 4 Rotary knob for output pressure not DPA D 5...

Страница 4: ...gy but restarts automatically if the pressure drops due to application operation With the DPA A it is possible to record the individual strokes of the drive piston using an external sensor and an addi...

Страница 5: ...packaging be recycled on the basis of its constituent materials exception oiled paper other waste S Please observe the warnings and instructions on the product and in these operating instructions S Us...

Страница 6: ...oles of the DPA Tightening torque 2 Nm With FDPA 40 flange mounting accessory Flange with 4 screws M4 in the threaded holes of the DPA Tightening torque 2 Nm Fit the flange to the wall with 2 screws M...

Страница 7: ...strokes has to be halved Information of the proximity sensor and the adding counter can be found in the operating instructions for these products Pneumatic connection for input pressure output pressur...

Страница 8: ...e DPA DPA 40 DPA 63 100 1 2 1 2 3 3 Fig 3 Type DPA 40 DPA 63 DPA 100 Connection number 1 Pneumatic connection 1 for input pressure 2 Pneumatic connection 2 for output pressure 3 Pneumatic connection 3...

Страница 9: ...uge A shows the input pressure pressure gauge B shows the output pres sure Use pressure gauges with a sufficient dial to show the input and output pressure 10 Technical data To show the output pressur...

Страница 10: ...g the com pressed air path S Make sure that equipment connected downstream of the DPA is designed to withstand the maximum output pressure which can be achieved Note The three way on off valve on the...

Страница 11: ...max 22 bar The max output pressure can be exceeded by up to 40 product dependent scatter of the regulator springs Setting the output pressure Note Pressure gauges are strongly recommended for checking...

Страница 12: ...as far as it will go 4 Disconnect the pneumatic ports of the DPA 8 Accessories Designation for Type Flange mounting DPA 40 FDPA 40 Foot mounting DPA 63 HUA 63 DPA 100 HUA 100 Pressure gauge set DPA 40...

Страница 13: ...evices at the Output Increase the input pressure Flow too low Silencer tubing or screw connectors with insufficient flow used Use only components of suffi cient sizes Insufficient air volume at compre...

Страница 14: ...10 4 5 16 5 16 4 10 4 16 4 16 4 10 4 16 4 16 Operating medium Filtered compressed air non lubricated grade of filtration 40 m Installation position as desired Ambient temperature C 5 60 Weight kg 1 5...

Страница 15: ...DPA Festo DPA 2017 07e 15...

Страница 16: ...zation is prohibited Offenders will be liable for damages All rights re served in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG Ruiter Stra e 82 73734 E...

Отзывы: