DPA
Festo DPA 2017-07e English
9
Pneumatic connection for pressure gauges
è
Fig. 4
1. Remove the screws plugs from the pressure gauge ports
4
.
2. DPA-40 only:
Seal off the pressure gauges with PTFE tape.
The pressure gauges for the DPA-63/100 have a PTFE coating. It is not necessary
to seal them with PTFE tape.
3. Firmly screw the pressure gauges into the ports
4
clockwise by hand. Pressure
gauge (A) shows the input pressure, pressure gauge (B) shows the output pres
sure.
Use pressure gauges with a sufficient dial to show the input and output pressure
(
è
10 Technical data). To show the output pressure, a pressure gauge with a
larger final value on the dial is required.
Exception: The DPA-…-10-MA-SET pressure gauge set (
è
8 Accessories) contains
two identical pressure gauges with a sufficient dial for the DPA-…-10.
DPA-40-10/16/D
DPA-63/100-10/16
4
4
DPA-63-D
DPA-100-D
4
4
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
Fig. 4
4. Align the pressure gauge with the spanner by screwing it in further by a maximum
of 1.5 turns.