Troubleshooting
Malfunction
Possible cause
Remedy
Rotating plate does not
move
Overload protection is active
Pressurise connection (B) and turn
the plate back against the direction
of rotation as far as possible. Doing
this causes the overload protection
and the locking mechanism, if
applicable, to engage audibly
Audible leakage
Send DHTG to Festo
Flow-control screw closed
completely
Open screw
Rotating plate does not
engage
End position not reached
Unscrew the adjusting screw for the
shock absorber until the rotating
plate engages
Overload protection is active
è
see above
Toothed disc and pinion stand tooth
on tooth
Please contact Festos Technical
Hotline
Hard metal impact at
the end position
Adjusting screw for shock absorber
unscrewed too far
Screw in adjusting screw
Shock absorber defective
Replace shock absorber
(
è
9 Dismantling and repairs)
Hard metallic knocking
in the locking
mechanism
Adjusting screw for shock absorber
screwed in too far (e. g. when
changing the direction of rotation)
Unscrew adjusting screw
Plate position incorrect
Overload protection engaged
incorrectly at 180° (plate offset 30°)
Force overload protection and turn
until it re-engages
Tab. 18