DDPC
Festo – DDPC –
201905b
English
13
12
Technical data
Size
80
100
Design
Double-acting standard cylinder with integrated
displacement encoder
Mounting position
as desired (as measuring cylinder and for
positioning)
vertical (with Soft Stop)
Operating medium
Compressed air to ISO 8573-1:2010 [6:4:4]
Note on operating/pilot medium
The pressure dew point must be at least 10 degrees
below the ambient and media temperature.
Operating pressure
[bar]
12 (as measuring cylinder)
[bar]
4 … 8 (for positioning / with Soft Stop)
Pneumatic connection
G3/8
G1/2
Ambient temperature
[°C]
–20 … +80
Theoretical force at 6 bar
Return
[N]
2721
4418
Advance
[N]
3016
4712
Max. torque for protection against rotation
dynamic
[Nm]
3
static
[Nm]
5
Impact energy at
the end positions
[Nm]
1.8
2.5
Travel speeds as measuring cylinder
minimum
[m/s]
0.05
maximum
[m/s]
1
Stroke reduction at the end positions
[mm]
25
Repetition accuracy with Soft Stop
end position
[mm]
0.5
intermediate position module
[mm]
± 2
Displacement resolution
With CASM or DADE
[mm]
0,005
With SPC11 or SPC200
[mm]
0,02
Accuracy of measurement
[mm]
Electrical connection
Cable with plug, round form, M12, 8-pin, A-coding
Cable length
[m]
1.5 (max. 30 m)
Output signal
analogue
Protection class to IEC 60529
IP65
1)
Higher speeds can be reached in combination with positioning controllers (see descriptions for the positioning controllers)
2)
L = Length of measuring system in meters