Festo — CPX(-M)-FB33/34/35/43/44/45 — 2022-05f
Technical data
35
10
Technical data
10.1
General
Characteristics
Bus node
General technical data
è
CPX system description CPX-SYS-…
Degree of protection by
housing,
in accordance with IEC 60529,
completely mounted, plug
inserted or cover cap installed.
IP65/IP67
Protection against electric
shock
By PELV circuits.
PELV = Protected Extra-Low Voltage
Tab. 26: General characteristics
Characteristics
CPX-FB33
CPX-M-FB34
CPX-M-FB35
Module code in the CPX Ter-
minal
–
Remote I/O
–
Remote Controller
215
164
216
165
217
166
Module identification
–
Remote I/O
FB33-RIO PROFINET
remote I/O
FB34-RIO PROFINET
RJ45 remote I/O
FB35-RIO PROFINET
LWL remote I/O
–
Remote Controller
FB33-RC PROFINET
I/O bus node
FB34-RC PROFINET
RJ45 bus node
FB35-RC PROFINET
LWL bus node
Power supply
Operating voltage/load voltage
è
CPX system description (CPX-SYS-…)
Internal current consumption of
the internal electronics at a
nominal operating voltage of 24
V DC,
from operating voltage supply
for electronics/sensors, U
EL/SEN
Typ. 85 mA
Typ. 85 mA
Typ. 155 mA
Separation of the PROFINET
interfaces to U
EL/SEN
Electrically isolated
by transformer up to
1500 V
Electrically isolated
by transformer up to
1500 V
Electrically isolated
by fibre-optic cable
Mains buffering time
10 ms
10 ms
10 ms
Tab. 27: Special characteristics of CPX-(M)-FB33/34/35
Содержание CPX-FB33
Страница 1: ...CPX M FB33 34 35 43 44 45 Bus node Operating instruc tions 548760 2022 05f 8161796...
Страница 39: ......