Festo CPX-FB33 Скачать руководство пользователя страница 1

CPX(-M)-FB33/34/35/43/44/45

Bus node

Operating instruc-

tions

548760

2022-05f

[8161796]

Содержание CPX-FB33

Страница 1: ...CPX M FB33 34 35 43 44 45 Bus node Operating instruc tions 548760 2022 05f 8161796...

Страница 2: ...Translation of the original instructions PI PROFIBUS PROFINET is a registered trademark of its respective trademark holder in certain countries...

Страница 3: ...g to the network 14 6 3 Ensuring the degree of protection 14 6 4 Power supply 15 7 Commissioning 15 7 1 Setting up PROFINET communication 15 7 2 Setting up MQTT communication 16 8 Parameterisation 17...

Страница 4: ...M FB45 from revision 45 CPX M FB45 Bus node CPX M FB45 from revision 45 Tab 2 Product versions Information on the revision levels of the product 4 2 2 Product variants There may be an updated version...

Страница 5: ...onnection to the higher order controller The PROFINET communicates in real time with the Real Time Protocol RT or the Isochro nous Real Time Protocol IRT The switch integrated in the bus node enables...

Страница 6: ...to the network or a PC using either a patch cable or crossover cable The crossover detection function must be activated in the control software if patch and crossover cables are used in the same syst...

Страница 7: ...al problems 4 2 Structure 4 2 1 Product design 1 1 2 2 3 3 3 3 4 4 5 5 6 6 Fig 1 Connection and display elements 1 LED displays 2 Memory card only for FB33 34 35 3 Network connection 4 DIL switches 5...

Страница 8: ...rt MQTT from Rev 53 from Rev 45 Tab 3 Required revision numbers for using the functions The bus nodes CPX M FB33 34 35 do not support MQTT The revision numbers of the hardware and software for the bus...

Страница 9: ...mode DIL switch 2 Description Factory setting 1 OFF 2 OFF Remote I O operating mode All functions of the CPX terminal are controlled by the PROFINET IO controller 1 ON 2 OFF Remote controller operati...

Страница 10: ...NET addressing Fieldbus device name IP address The configuration data can be transferred to the new bus node with the memory card when replacing a bus node The data on the memory card have priority ov...

Страница 11: ...location of the network interface of the bus node CPX M FB34 44 Bushing Pin Signal Explanation RJ45 Push pull 1 TD Transmitted data Transmit Data 2 TD Transmitted data 3 RD Received data Receive Data...

Страница 12: ...ce with the specifications for PROFINET networks Network connectors Cable specification NECU MS D12G4 C2 ET Ethernet cable shielded Cat 5 5e 6 8 mm 0 14 0 75 mm2 max 100 m PROFINET end to end link 22...

Страница 13: ...e it against being switched on again CPX M FB35 45 only permissible on metal linking Disassembly 1 Unscrew screws 2 Carefully lift the bus node Assembly 1 Check seal and sealing surfaces and insert th...

Страница 14: ...ntional modification For additional information Guidelines and standards for security in information technology e g IEC 62443 ISO IEC 27001 Use of switches and routers The switch integrated in the bus...

Страница 15: ...on sequence First switch on the operating voltage supply of all network stations and then the operating power supply of the open loop control CPX M FB34 cyclical process data exchange can freeze in ex...

Страница 16: ...Information on troubleshooting in the event of incorrect behaviour 9 Diagnostics 7 2 Setting up MQTT communication Requirement the feature must be activated This can be checked via the web server 1 Se...

Страница 17: ...Identifier option may only be activated if the broker used supports it Retain Flag The Retain Flag option causes the MQTT server to save the last published message for each topic As a result other cl...

Страница 18: ...nostic memory can only be set via the CPX MMI or CPX FMT Device specific parameters Diagnostic message filter Undervoltage UOUT UVAL Only available for bus nodes from Rev 14 Displayed in the hardware...

Страница 19: ...Intel LSB MSB Little Endian Factory setting process values are displayed in Intel format The least significant bit is on the right and the most significant bit on the left Byte order Motorola MSB LSB...

Страница 20: ...oller 9 2 Diagnostics via LED displays Various status LEDs are available for diagnostics at the bus node They show hardware errors configu ration errors and bus errors directly on site which enables f...

Страница 21: ...nergy LED Sequence Status Error handling LED is off Maintenance action not required PROFIenergy function not activated LED is yellow Maintenance action required Check Operating voltage Plug Fibre opti...

Страница 22: ...Status Error handling LED is off Physical network connection not detected Check network connection net work cable LED on Network connection is OK LED flashes Both LEDs flashing synchro nously module l...

Страница 23: ...r elec tronics and sensors outside the tolerance range 1 Check operating voltage 2 Rectify short circuit overload 3 Depending on the parameter isation Factory setting the sensor supply voltage will be...

Страница 24: ...y undervoltage 2 Depending on the parameter isation Factory setting the load voltage supply will be switched on again automati cally after the undervoltage has been eliminated Switch power supply off...

Страница 25: ...agnostics 25 SE System Error LED Sequence Status Error handling LED flashes 2x Error error class 2 Description of error numbers in the CPX system description CPX SYS LED flashes 3x Serious error error...

Страница 26: ...essary LED flashes Force is active The Forcen function is enabled Force mode function no 4402 CPX system description CPX SYS Tab 22 CPX terminal status LED M The display of the Forcen function has pri...

Страница 27: ...cription of the operator unit CPX MMI 9 6 Diagnostics via CPX FMT The Festo Maintenance Tool FMT offers PC based diagnostic functions via a graphical representation of the CPX terminal e g status disp...

Страница 28: ...it undershot 10 7 Upper critical limit exceeded 11 1 Short circuit at valve 13 6 Wire break at valve 65 64 PROFIsafe addresses F_Dest_Add different 69 72 Parameterisation error error in safe parame te...

Страница 29: ...ION String Serial number of the CPX bus node CPX FBD_SERIAL String Current time of the CPX bus node CPX FBD_TIMESTAMP String Current time quality of the CPX bus node No synchronization Hard synchroniz...

Страница 30: ...re revision of the CPX module CPX Mx_HWVER String Number of parameters of the CPX module CPX Mx_PARAMCOUNT Number Name of the parameter of the CPX module CPX Mx Px_NAME String Value of the parameter o...

Страница 31: ...y CPX FBD_TIMESTAMP_QUALITY TemplateSelection TEMPLATE_SELECTION TemplateVersion TEMPLATE_VERSION TelegramSendReason Tx_TELEGRAM_SEND_REASON PNDeviceName PN PDN HostName CPX HOSTNAME InterfaceList IPA...

Страница 32: ...if the connection to Broker is interrupted by the bus node as a result of an MQTT configuration change Topic TOPIC_PREFIX OFFLINE TEMPLATE_VERSION TEMPLATE_SELECTION Payload OFFLINE Timestamp CPX FBD_...

Страница 33: ...ned by the number of input and output bytes of the respective module The data within the fields must be interpreted according to the module s user manual The byte order corresponds to the order of the...

Страница 34: ...PNErrorCode CPX Dx_DIAG_MESSAGE_ID_PROFINET MessageType CPX Dx_DIAG_MESSAGE_TYPE MessageStatus CPX Dx_DIAG_MESSAGE_STATUS MessageId CPX Dx_DIAG_MESSAGE_ID_CPX MessageText en US CPX Dx_DIAG_MESSAGE_TEX...

Страница 35: ...Remote I O FB33 RIO PROFINET remote I O FB34 RIO PROFINET RJ45 remote I O FB35 RIO PROFINET LWL remote I O Remote Controller FB33 RC PROFINET I O bus node FB34 RC PROFINET RJ45 bus node FB35 RC PROFI...

Страница 36: ...NET LWL bus node Power supply Operating voltage load voltage CPX system description CPX SYS Internal current consumption of the internal electronics at a nominal operating voltage of 24 V DC from oper...

Страница 37: ...X terminal configuration via CPX FMT CPX terminal diagnostics via fieldbus communication and the control system Web server functionality Representation of the PROFINET network structure CPX ter minal...

Страница 38: ...hings D coded 4 pin 2 x RJ45 bushings push pull AIDA con forming 2 x SCRJ bushings push pull AIDA con forming Crossover detection Auto MDI Auto MDI Max addressing volume of out puts inputs operating m...

Страница 39: ......

Страница 40: ...2022 all rights reserved to Festo SE Co KG Copyright Festo SE Co KG 73734 Esslingen Ruiter Stra e 82 Deutschland Phone 49 711 347 0 Internet www festo com...