3
Parameterisation
18
Festo – CPX-E-PB-EN – 2017-07 – English
Slot 2: Channel-specific module parameters
Index
Name
Length
[byte]
Access
Data record
number
Function number
16
Fault mode
64
r
2
3888
17
Fault state
64
r
3
3952
18
Force mode Outputs
64
r
4
4016
19
Force state Outputs
64
r
5
4080
20
Force mode Inputs
64
r
6
4144
21
Force state Inputs
64
r
7
4208
22
Global operating system data
40
r
8
4792
1) r = read access; w = write access
2) Siemens S7: “S7-compatible” parameter setting
Tab. 3.2
The data records (system parameters, module data and module parameters) can be read and written indirectly at
Slot 3.
For this purpose, the command box is assigned a slot number, index number and offset (Byte 4 is reserved).
Read and write procedures can be performed using Read Box and Write Box.
Slot 3: Indexed addressing of the objects
Index
Name
Length
[byte]
Access
Data record
number
Function number
16
Command box
4
r/w
9
–
17
Read Box
64
r
10
–
18
Write Box
64
w
11
–
1) r = read access; w = write access
2) Siemens S7: “S7-compatible” parameter setting
Tab. 3.3
Slots 100 … 147: Module data and module parameters
Index
Name
Length
[byte]
Access
Data record
number
16
Module configuration
16
r/w
72
16 + 16m
17
Module serial number
4
r
73
784 + 4m
18
Diagnostic data module
4
r
74
2008 + 4m
19
Reserve
4
r/w
75
3224 + 4m
20
Set module configuration
8
r/w
76
4408 + 8m
21
Module parameter
64
r/w
77
4828 + 64m
22
Module parameter sets
16
r
78
976 + 16m
23
Diagnosis of all input channels
64
r
79
–
24
Diagnosis of all output channels
64
r
80
–
25
Module Fault mode
64
r/w
81
–
26
Module Fault state
64
r/w
82
–
27
Module forcen: Outputs
64
r/w
83
–
28
Module forcen: Outputs
64
r/w
84
–
29
Module forcen: Inputs
64
r/w
85
–
30
Module forcen: Inputs
64
r/w
86
–
1) r = read access; w = write access
2) Siemens S7: “S7-compatible” parameter setting
3) m = Module number
Tab. 3.4