Festo CPV..-GE-ASI-... 2017-11e English
9
4.2 Configure the load voltage (additional supply)
Caution
Functional damage
S
Switch on the power supply only if the DIP switch is
positioned at a permitted setting (see following
table).
1
DIP switch for
configuring the
voltage supply on
the bottom of the
sub-base
1
Setting
DIP switch setting
1)
With load voltage
Supplying the valves via a separate load
voltage connection (additional supply)
1, 2: Off
3, 4: On
Without load voltage
Supplying the valves via the AS-Interface
bus (seal connection “24 V DC” with a
blanking plug type ASI-SD-FK-BL).
1, 2: On
3, 4: Off
1)
black = pressed
Instructions on removing the electric sub-base can be
found in the Pneumatics Manual.