![Festo CPV GEASI-4 Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/festo/cpv-geasi-4-series/cpv-geasi-4-series_brief-description_2284143011.webp)
Festo CPV..-GE-ASI-... 2017-11e English
11
Please note with branch lines:
–
the maximum total length of the AS-Interface bus:
100m (without repeater/extender).
–
the cable length of the load voltage connection
(depends on the current consumption of the valve
terminal and fluctuations in load voltage).
Pin assignment “Bus” (yellow cable):
1
Pin 2: AS-Int (brown)
2
Pin 1: AS-Interface - (light blue)
Pin assignment “24 V DC” (black cable):
*)
3
Pin 2: + 24 V (brown)
4
Pin 1: 0 V (blue)
1
2
3
4
*)
Can be configured via DIP switch, see section 4.2.
For connecting the valve terminal use the Festo cable
sockets type ASI-SD-FK.... You will then comply with
protection class IP65. Proceed as follows:
1. Press the AS-Interface cable into the upper part of the
cable socket.
2. Make sure that the cable is free of tension.
3. If necessary, insert the cable socket or a blanking plug
and screw it tight (max. 0.3 Nm).
Seal open flat cable ends with the Fest cable cap type
ASI-KK-FK or the cable sleeve type ASI-KT-FK. In this way
you will avoid leakage currents and comply with protection
class IP65.