Festo CPV..−GE−CC−8 0304NH English
15
2.2 Pin assignment of power supply connection
2
M12 connection
Pin no.
1
2
4
3
1: 24 V DC operating voltage for the
electronics and inputs
1)
2: 24 V DC load voltage for the valves
3: 0 V
4: Earth/ground connection
1)
On the extension connection of connected modules
2.3 Example of connection with PELV power unit and
potential equalization
1
PE
2
Potential
equalization
3
Load voltage
can be switched off
separately and
external fuses
4
Earth connection
pin4 (max. 3 A)
5
Connect the earth
connection of the
CPV Direct with low
impedance to FE
PS
MNS
3 1 2 4
1 2
3
4
2
2 A
2 A
5