Festo CPV..−GE−CC−8 0304NH English
13
1
User instructions
English
The CPV valve terminal with field bus direct connection
(CPV Direct) is intended exclusively for use as a slave on
the field bus CC link.
The maximum values specified in the section Technical
specifications" must be observed here. Detailed informa
tion can be found in the manual P.BE−CP−CC−.. .
Warning
S
Switch off the power supply before connecting or
disconnecting plugs (otherwise this could lead to
functional damage).
S
Use only power units which guarantee reliable
isolation of the operating voltages as per IEC 742/
EN60742/VDE 0551 with at least 4 kV isolation
resistance (Protected Extra Low Voltage PELV).
Switch power packs are permitted, providing they
guarantee reliable isolation in accordance with
EN60950/VDE0805.
S
Connect an earth conductor of sufficient cross−
sectional area to the terminal marked with the earth
symbol.
S
Commission only a CP system which has been fitted
and wired completely.
If the terminal is to be used as an explosion−proof oper
ating medium, make sure that:
S
the electrical connections are not disconnected when
power is still applied.
S
the completely fitted valve terminal with all plugs,
adapters and protective caps complies at least with
protection class IP64.