Address selector button

If the same address is assigned to both slaves, no clear
access to the slaves is possible.

In this case slave 1 can be disconnected from the AS-Inter­
face bus with the aid the address selector button. You can
unlock the pushbutton by pressing it. Slave 1 will then be
disconnected from the AS-Interface bus. If the AS-Inter­
face bus voltage is applied, the address selector LED will
light up to indicate that slave 1 has been disconnected
from the AS-Interface.

Please note

The red address selector LED must not light up when
the valve terminal is operated.
If the adress selector button has been unlocked: 
Before connecting the valve terminal to the AS-Inter­
face bus, therefore always lock the address selector
button by pressing it again.

3.3 Address assignment of the valves

During addressing, valve terminal CPV..-GE-ASI-8E6A-...
behaves like two individual slaves each with 4 inputs and
3 outputs (see sections 3.1 and 2).

The following fittings are possible for the two valve
terminal halves:

Содержание CPV-GE-ASI-8E6A-Z M8 Series

Страница 1: ...Brief description CPV valve terminal with AS Interface type CPV10 14 ASI 8 E6A English 8101710 2018 11b 8101712 Compact performance...

Страница 2: ...Ruiter Stra e 82 73734 Esslingen Germany Internet http www festo com E Mail service_international festo com Reproduction distribution or sale of this document or communication of its contents to other...

Страница 3: ...stems and valve terminals may only be installed by personnel especially trained for this purpose Detailed information on the design and addressing of your bus system can be found in the manual for you...

Страница 4: ...ption fields for addresses 8 LED status display for valves yellow 9 Valve plates slave 2 aJ Valve plates slave 1 aA Load voltage connec tion for valves aB PWR LED power green Fault LED fault red PWR L...

Страница 5: ...f the inputs and outputs valves Slave 1 Inputs I0 I3 outputs O0 O2 Slave 2 Inputs I4 I7 outputs O4 O6 Automatic addressing with the function Automatic address assignment of the master is not possible...

Страница 6: ...ype ASI PRG ADR with adapter cable type KASI ADR Factory setting Slave 1 address 1 A slave Slave 2 address 1 B slave The addressing device scans the existing slaves in the AS Interface network S Assig...

Страница 7: ...ess selector LED will light up to indicate that slave 1 has been disconnected from the AS Interface Please note The red address selector LED must not light up when the valve terminal is operated If th...

Страница 8: ...FF 3 OFF 4 ON J 2 Addresses of the solenoid coils for AS Interface address n m 3 Addresses or LEDs of the solenoid coils 14 4 Addresses or LEDs of the solenoid coils 12 5 Valve plates with 2 valve sol...

Страница 9: ...nections with the protective caps type ISK M8 Only in this way can you comply with protection class IP65 Please note The inputs are resistant to short circuits If a short cir cuit occurs the slave wil...

Страница 10: ...e AS Interface has an integrated watchdog function which resets the outputs if there is a bus communica tion failure Warning Use power supplies which guarantee reliable electrical isolation of the ope...

Страница 11: ...Pin assignment 24 V DC black cable 3 Pin 2 24 V brown 4 Pin 1 0 V blue 0 1 1 2 3 4 For connecting the valve terminal use the Festo cable sockets type ASI SD FK You will then comply with protection cla...

Страница 12: ...can be fitted with double solenoid and or single solenoid valves During conversion the new valve terminal configuration must be set on the DIP switches on the bottom of the electric sub base 1 DIP swi...

Страница 13: ...inserted or provided with protective cap IP65 Relative humidity 95 non condensing Electromagnetic compatibility EMC interference emission EMC resistance to interference See declaration of conformity w...

Страница 14: ...correct polarity Residual ripple Current consumption for 8 valves when switched on 26 4 V 2 when switched on 20 4 V 2 after current reduction stationary 26 4 V after current reduction stationary 20 4...

Отзывы: